Contrast Adjustment (Pd-137 Board); Color Adjustment (Pd-137 Board) - Sony DSC-P1 Service Manual And Parts List

Hide thumbs Also See for DSC-P1:
Table of Contents

Advertisement

5. Contrast Adjustment (PD-137 Board)

Set the level of the VIDEO signal for driving the LCD to the
specified value.
If deviated, the LCD screen image will be blackish or saturated
(whitish).
Mode
Signal
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Specified Value
Adjusting method:
Order Page Address Data
1
0
2
5
3
D
4
D
Processing after Completing Adjustments:
Order Page Address Data
1
5
2
0
A
Pedestal
A: Between the pedestal and 10 setps peak
Downloaded from
www.Manualslib.com
PLAY
Arbitrary
Pin 9 of CN881 (VG)
External trigger: Pin 8 of CN881
(PEARL COM)
Oscilloscope
D
D4
A = 2.50 ± 0.05 Vp-p (TYPE ST)
A = 2.24 ± 0.05 Vp-p (TYPE SA)
Procedure
01
01
F1
03
Change the data and set the
D4
voltage (A) to the specified
value.
D4
Press PAUSE button.
Procedure
F1
00
01
00
10 steps peak
2H
Fig. 5-1-24
manuals search engine

6. Color Adjustment (PD-137 Board)

Set the color saturation to the standard value.
If, deviated, the color will be dark or light.
Mode
Signal
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Specified Value
Adjusting method:
Order Page Address Data
1
0
01
2
5
F1
2
D
D1
4
D
D1
Processing after Completing Adjustments:
Order Page Address Data
1
5
F1
2
0
01
White 100%
Green
A
A: Between the white 100% (Reference level) and green
Fig. 5-1-25
5-30
PLAY
Arbitray
Pin 9 of CN881 (VG)
External trigger: Pin 8 of CN881
(PEARL COM)
Oscilloscope
D
D1
A = 444 ± 50 mVp-p (TYPE ST)
A = 308 ± 50 mVp-p (TYPE SA)
Procedure
01
04
Change the data and set the
voltage (A) to the specified
value.
Press PAUSE button.
Procedure
00
00
2H

Advertisement