5. Contrast Adjustment (SY-096 board)

Set the level of the VIDEO signal for driving the LCD to the specified
value. If deviated, the screen image will be blackish or saturated
(whitish).
Mode
PLAY (
Subject
Arbitrary
Measurement Point
Data of page: 80, address: 02
Measuring Instrument
Adjustment Page
8F
Adjustment Address
7C
Specified Value
01
Note1: A memory stick must be inserted.
Adjusting method:
Order Page Address Data
1
2
8F
89
44
3
80
00
00
4
80
02
00
5
80
01
80
6
80
00
05
7
8
80
02
9
10
Note2: If the data is other than "01", adjustment has errors. See the
following table.
Data of page: 80,
Contents of adjustment error
address: 02
01
Normally finished
10
Reached an upper limit
20
Reached a lower limit
30
Time out
40
Out of adjustment range
50
Adjustment is impossible
)
Procedure
Check that "1. Data Setting
during EVF System
Adjustments" is performed.
Set the data.
Set the data.
Set the data.
Set the data.
Set the data.
Wait for 1 sec.
Read the data, and check it is
"01". (Note2)
Wait for 1 sec.
If finish the EVF system
adjustments, release the data
setting.
(See "1. Data Setting during
EVF System Adjustments".)
6. V COM Adjustment (SY-096 board)
Set the DC bias of the common electrode drive signal of LCD to the
specified value.
If deviated, the LCD display will move, producing flicker and
conspicuous vertical lines.
Mode
Subject
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Specified Value
Note1: A memory stick must be inserted.
Adjusting method:
Order Page Address Data
1
2
8F
8C
3
80
00
4
80
02
5
80
01
6
80
00
7
8
80
02
9
10
Note2: If the data is other than "01", adjustment has errors. See the
following table.
Data of page: 80,
address: 02
01
Normally finished
10
Reached an upper limit
20
Reached a lower limit
30
Time out
40
Out of adjustment range
50
Adjustment is impossible
6-33
DSC-F828
PLAY (
)
Arbitrary
Data of page: 80, address: 02
8F
74
01
Procedure
Check that "1. Data Setting
during EVF System
Adjustments" is performed.
03
Set the data.
00
Set the data.
00
Set the data.
80
Set the data.
07
Set the data.
Wait for 1 sec.
Read the data, and check it is
"01". (Note2)
Wait for 1 sec.
If finish the EVF system
adjustments, release the data
setting.
(See "1. Data Setting during
EVF System Adjustments".)
Contents of adjustment error