Omega Engineering High Speed Load Cell Interface Card LCIC-WIM-BEN User Manual page 78

High speed load cell interface card
Table of Contents

Advertisement

E.6 Commands
Enter & Exit Fill Mode
F
Enter Fill Mode (from General Mode)
x
Exit Fill Mode (to General Mode) (small 'x')
Inside the Fill Mode
g
Start filling ('g' stands for 'go') (like input #2 does).
t
Terminate an error status (like input #3 does).
e
Emergency stop (like input #4 does).
r
Get filling(s) report
Response Example:
# 1 A= 40.99 Tr= 6.65 Cv= 0.00 Ft= 7527 ms St= 2554 ms Cc= 0
Legend: Filling #1, Actual (=final) weight=40.99,
Tare=6.65, Correction Value=0.00,
Fast time=7527 ms, Slow time=2554 ms,
Completion Code=0 (0 is normal, otherwise it's an error code).
Notes:
1. The actual (final) weight (40.99 in the example) is:
* net weight if Auto Tare is selected
* gross weight if Auto Tare is not selected.
2. The reports are accumulated in a FIFO whose size is 30
fillings. That is, only up to last 30 reports are available.
Note: The FIFO size (30) is subject to change in the various
versions.
3. Please refer also to section 3.3.2.1.4.
F
Get fillings summary:
Number of normal fillings.
Number of each error type cases for each error type
that occurred at least once.