Category
Variable Name
Calibration_Name
Calibration_Date
Calibration_Time
Calibration
Info
Full_Capacity
Maximum_Load
Load_Cell_Output
Filtering
Variables Table
Unit
Resolution
There are two filters. The first filter is
Filter1
every Decimator-th result from the 1st
Filter2
*
a board reset, so it is a slow function.
Decimator
Description
Name of calibration
Calibration date (MMDDYY).
Calibration time
(HHMM, e.g., 1545).
Weighing unit:
ton, kg, g, lb or oz.
Weighing resolution:
0.0001, 0.0002, 0.0005, 0.001,
0.002, 0.005,
0.01, 0.02, 0.05,
0.1, 0.2, 0.5,
1, 2, 5,
10, 20 or 50.
Full capacity of the load cell.
Maximum applied load on the
load cell.
Output of the load cell:
0 = Unknown
1, 2 or 3 = 1, 2 or 3 mV/V.
basically a 1st level moving average
filter of size Filter1 (2-256). Then
depending on Decimator (1-1000),
level filter is put through another
moving average filter of size Filter2
(2-256), which is the second filter .
Setting these three variables causes
Therefore, in order to set all of them
there is one more option: the method
Set_Filtering , which works faster
than three individual activations of
the Set_Variable method.
39
Get
Set
V
V
V
V
V
V
V
V
V
*
V
*
V
*