Omega Engineering High Speed Load Cell Interface Card LCIC-WIM-BEN User Manual page 75

High speed load cell interface card
Table of Contents

Advertisement

E.4.2 Filling By = Time
E.4.2.1 Filling by Time Parameters
Setpoint
#x
The required total filling time when the user selects
setpoint
#x (x
= 1, 2 or 3).
Slow Amount
The required slow filling time, in % of the current Setpoint
(a tip shows the value of Slow Amount in ms).
Specify '0' when only one speed is required.
E.4.2.2 Stabilization Criterion (Stop)
At the end of a filling cycle the board waits for the scale to stabilize
before proceeding to the next cycle. The size of this waiting delay is
specified by the ''Delta Time'' parameter.
Delta Time
See the description above.
E.4.3 Fast Speed Config
Option1
Fast Speed = Output #1
Slow Speed = Output #2
Option2
Fast Speed = Output #1 + Output #2
Slow Speed = Output #2