6. Installation

6-1. Drill one 0.5"(12.7mm) hole at the central of the RFL200C / IP-RFL200C on mullion or wall
mount. Route the cable of reader module through the central hole.
6-2. Drill one 0.39"(10mm) in right horizontal and 1.74"(44.4mm) in upper vertical through the
central hole. And drill the other 0.33"(8.5mm) in left horizontal and 1.59"(40.6mm) in under
vertical through the central hole.
6-3. Push reader module on mullion or wall mount then install the main unit using two 6-32 or M3
screws.