11. Operation

11-1. When the RFL200C / IP-RFL200C is powered on,
① All LEDs are lit red or green, then they flash on and off twice and then turn off.
② Then, red LEDs are lit sequentially from bottom to top.
③ The RFL200C / IP-RFL200C beeps once.
11-2. When a registered tag is read on the RFL200C / IP-RFL200C or the exit button is pressed,
① All LEDs switch from red to green, then they turn off sequentially from top to bottom. After
all LEDs are off, they turn on red again.
② The door opens for a predefined length of time and the first two LEDS from the top turn red,
indicating the open status of the door.
③ The RFL200C / IP-RFL200C beeps once.
11-3. When an unregistered tag is read on the RFL200C / IP-RFL200C,
① All LEDs are lit red, then they flash on and off twice and stay on.
② The RFL200C / IP-RFL200C beeps twice.
11-4. When a tag is read on the RFL200C / IP-RFL200C while the door is open.
① The first two LEDs from the top still stay lit green, indicating the open status of the door.
The rest of the LEDs indicate the authentication status (access granted or denied).