Samsung MIM-E03*N User Manual page 37

Air to water heat pump -mono control unit
Hide thumbs Also See for MIM-E03*N:
Table of Contents

Advertisement

• Code 30✴✴ : User's options for domestic hot water(DHW) tank heating
3011 : Application of DHW tank in user's system
302✴ : Heat pump variables for tank temp. control and combination with booster heater
303✴ : Booster heater variables for combination with heat pump
304✴ : Periodical disinfection heating of water tank
305✴ : Off timer for power DHW mode by Forced DHW of wired remote controller
3061 : Combination of external field solar panel for with heat pump for DHW heating
307✴ : Default direction of the DHW valve or Zone #1, #2 valve
When the 3way valve is applied to DHW Valve terminal block instead of 2way valve, default direction is Space
Heating (Room)
Main Menu &
Sub Menu Function
Code
DHW Code
Domestic Hot Water Tank
30✴✴
Heat Pump
Booster Heater
Disinfection
Forced DHW operation
Solar Panel/DHW Thermostat
Direction of DHW valve
Field Setting Value
Description
Sub Code
Application
Max Temp
Stop
Start
Min. Space heating
operation time
Max. DHW operation time
Max. Space heating
operation time
Application
Delay Time
Overshoot
Compensation Temp
Application
Interval
Start Time
Target Temp
Duration
Timer OFF Function
Timer Duration
H/P Combination
DHW Tank
ENGLISH-37
Default
Min
0(No)
0
✴✴11
50
45
✴✴21
2
2
✴✴22
5
5
✴✴23
5
1
✴✴24
30
5
✴✴25
3
0.5
✴✴26
1(On)
0(Off)
✴✴31
20
20
✴✴32
0
0
✴✴33
10
0
✴✴34
1(On)
0(Off)
✴✴41
Fri(5)
Sun(0)
✴✴42
23
0
✴✴43
70
40
✴✴44
10
5
✴✴45
0(Off)
0
✴✴51
6
3
✴✴52
0
0
✴✴61
0(Room)
0
✴✴71
Max
Step
Unit
1(Yes)
-
-
50
1
˚C
10
1
˚C
20
1
˚C
20
1
min
95
5
min
10
0.5
hour
1
-
-
95
5
min
4
1
˚C
20
1
˚C
1
-
-
All(7)
1
day
23
1
o'clock
70
5
˚C
60
5
min
1(On)
-
-
(x10)
30
1
min
2
-
-
1(Tank)
-
-