Step 8. Convert to lp gas (optional)

All new gas ranges are shipped from the
factory set up to use natural gas. Any
Samsung gas range can be converted to use
LP gas. Refer to page 97 in the User Manual
to contact a qualified service technician.
The conversion process should only be
performed by a qualified LP gas installer.
Conversion instructions and LP orifices will
be supplied with the LP conversion kit. The
conversion to LP requires all burner orifices
to be changed (5 surface burners).
In addition, the nozzle on the gas pressure
regulator needs to be reversed. All replaced
orifices must be left with the consumer,
including the instructions and retrofit sizes
and orifice indication.
Checking the flame quality all burner after
converting to lp gas.
(Install)NY58J9850WS_DG68-00693A-01_EN.indd 37
BURNER ORIFICE SIZES AND OUTPUT
RATINGS (LP Gas [Propane] 10 in WCP)
Burner
BTU Rate
Location
RF
16,500
LF
11,500
RR
4,000
LR
7,500
CTR
7,500
BAKE
15,000
BROIL
14,500
BURNER ORIFICE SIZES AND OUTPUT
RATINGS (Natural Gas 5 in WCP)
Burner
BTU Rate
location
RF
22,000
LF
15,000
RR
5,000
LR
9,500
CTR
9,500
Orifice Size
[mm]
In: 0.46/
Out: 0.83 (2 pcs)
1.04
0.62
0.83
0.83
1.15
1.12
Orifice size
[mm]
In: 0.85/
Out: 1.36 (2 pcs)
1.78
1.01
1.40
1.38
English 37