Step 3. Convert To Lp Gas (Optional) - Samsung NX58J7750S Series Installation Manual

Free-standing gas range
Hide thumbs Also See for NX58J7750S Series:
Table of Contents

Advertisement

Available languages

Available languages

Flexible connector hookup
Installer: Inform the consumer of the location of the gas shut-off valve.
Gas Shut-Off Valve
0.5-in or 0.75-in Gas Pipe
Adapter
Flex Connector
(6-ft max.)
Adapter

Step 3. Convert to lp gas (optional)

All new gas ranges are shipped from the
factory set up to use natural gas. Any
Samsung gas range can be converted to use
LP gas. Refer to page 78 in the User Manual
to contact a qualified service technician.
The conversion process should only be
performed by a qualified LP gas installer.
Conversion instructions and LP orifices will
be supplied with the LP conversion kit. The
conversion to LP requires all burner orifices
to be changed (5 surface burners and
2 oven burners).
In addition, the nozzle on the gas pressure
regulator needs to be reversed. All replaced
orifices must be left with the consumer,
including the instructions and retrofit sizes
and orifice indication.
If your area requires a rigid pipe hookup,
Tubing Line to
contact a qualified installer, service agency,
Oven Burner
Control Valve
or gas supplier.
Tubing Line
The gas shut-off valve should be installed
to Cooktop
Control
in an accessible location in the gas piping,
Manifold
external to the appliance, for the purpose
Pressure
of turning on or shutting off the gas to the
Regulator
appliance.
BURNER ORIFICE SIZES AND OUTPUT
RATINGS (LP Gas [Propane] 10 in WCP)
Burner
Location
RF
LF
RR
LR
CTR
BAKE
BROIL
BURNER ORIFICE SIZES AND OUTPUT
RATINGS (Natural Gas 5 in WCP)
Burner
location
RF
LF
RR
LR
CTR
BAKE
BROIL
NOTE
NOTE
BTU Rate
14500
11500
4000
7500
7500
15000
14500
BTU Rate
18000
15000
5000
9500
9500
18000
13500
Orifice Size
[mm]
1.12
1.04
0.62
0.83
0.83
1.15
1.12
Orifice size
[mm]
1.92
1.78
1.01
1.40
1.38
1.90
1.64
English 29

Advertisement

Table of Contents
loading

Table of Contents