Section 2. - Operating Parameters
A. Temperature
Since the FTB600B Series has printed circuit boards molded into the
body of the meter it is strongly recommended that 180°F not be
exceeded. Exceeding 180°F can cause irreparable damage to the circuit
boards.
B. Flow Ranges
The FTB600B Series is available in six different sizes, which cover a
flow range from 0.1 to 120 lpm.
Specific flow ranges
FTB601B
FTB602B
FTB603B
FTB604B
FTB605B
FTB606B
0.1 to 2 lpm
0.3 to 9 lpm
0.5 to 15 lpm
1.0 to 30 lpm
2.5 to 75 lpm
4.0 to 120 lpm
Over range may permanently damage the flow meter.
FTB600B Series
Operating Parameters
(0.03 to 0.53 gpm)
(0.08 to 2.38 gpm)
(0.13 to 3.96 gpm)
(0.26 to 7.93 gpm)
(0.66 to 19.8 gpm)
(1.32 to 32 gpm)
WARNING
2
3