Omega CDTX-90 Series User Manual page 5

Conductivity/resistivity transmitters
Table of Contents

Advertisement

CDTX-90-1 Terminal connections
Terminals 3 and 4: Loop Power
12-24 VDC ±10% system power
and current loop output.
Max. loop impedance:
50 Ω max. @ 12 V
325 Ω max. @ 18 V
600 Ω max. @ 24 V
System Pwr
4
Loop -
System Pwr
3
Loop +
AUX
2
Power -
AUX
1
Power +
Terminals 1-2: Auxiliary power
Provides DC power to measurement
circuit. Required for all CDTX-90
systems.
CDTX-90-1 System Power/Loop Connections
Stand-alone application, no current loop used
Transmitter
Terminals
Sys. Pwr.
4
Loop -
Sys. Pwr.
3
Loop +
AUX
2
Power -
1
AUX
Power +
Connection to a PLC/Recorder, separate supply
Transmitter
Terminals
Sys. Pwr.
4
Loop -
Sys. Pwr.
3
Loop +
AUX
2
Power -
AUX
1
Power +
AUX power required for all CDTX-90 systems.
6
Output -
5
Output +
Internal open-collector
output circuit
S
D
Isolation
Terminals 5-6: Open-collector Output
A transistor output, programmable (see CALIBRATE menu) as High or Low setpoint with
adjustable hysteresis and proportional pulse (to 400 pulses per minute maximum).
May be disabled (Off) if not used.
Power Supply
DC 12 - 24 V
Power
-
Supply
Power
+
Supply
DC 12 - 24 V
Power
-
Supply
Power
+
Supply
PLC or Recorder
-
Loop Input
4-20 mA in
Loop Input
+
4-20 mA in
Terminals 7-10: Sensor input
7 is conductivity input
8 is temperature input
9 is the isolated signal ground
10 is the sensor earth ground
10
9
8
7
15Ω
Output --
Output +
Connection to a PLC with built-in power supply
Transmitter
Terminals
Sys. Pwr.
4
Loop -
Sys. Pwr.
3
Loop +
AUX
2
Power -
1
AUX
Power +
Example: Two transmitters connected to PLC/Recorder
Transmitter 1
Sys. Pwr.
4
Loop -
Sys. Pwr.
3
Loop +
AUX
2
Power -
AUX
1
Power +
Transmitter 2
Sys. Pwr.
4
Loop -
Sys. Pwr.
3
Loop +
AUX
2
Power -
AUX
1
Power +
Sensr Gnd
(SHIELD)
Iso. Gnd
(BLACK)
Temp. IN
(WHITE)
Signal IN
(RED)
PLC
Terminals
Power Supply
-
Ground
Power
+
Supply
-
Loop Input
4-20 mA
+
Loop Input
4-20 mA
Internal PLC
Connection
with separate power supply
DC 12 - 24 V
Power
Supply
Power
Supply
PLC or Recorder
Channel 1
-
4-20 mA in
+
Channel 1
4-20 mA in
Channel 2
-
4-20 mA in
+
Channel 2
4-20 mA in
page 5

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents