Fl45200a series in-line flowmeters with half union adapters

Advertisement

Page 2
FOLLOW INSTRUCTIONS TO AVOID FAILURE
1. Finish piping to be plumb and true.
2. Polysulfone and other exotic plastics cannot tolerate P.V.C. glue and pipe
dope. Even the fumes can cause crazing.
3. Use teflon tape for threaded joints.
4. Make up assembly and fit pipes, then: remove F.M. after glue fumes are
vented out.
5. Meter cannot support attached pipes.
6. Excessive vibration may cause float to give poor reading or cause possible
fracture.
7. Wall, floor, and ceiling mounts to be carefully aligned and sturdy. A support
should be at top and bottom of meter. See drawing.
8. Hand tighten union nuts. No wrenches.
9. Protect meter from ultra violet (UV) rays.
10. VALVES - avoid system that will impose a sudden burst of flow to the meter.
Such a burst will cause the float to impact the guide assembly with destructive
force. Magnet, solenoid, or other quick opening valves cannot be used unless
meter is protected against sudden burst of flow.
11. Failure to comply VOIDS WARRANTY!
Part Number
(316 SS Float)
FL45201A*
FL45202A
FL45203A
FL45204A
FL45205A
FL45206A
FL45230A
®
* Teflon
float
CAUTION
Part Number
(Hastelloy C Float)
-
FL45202A-HL
FL45203A-HL
FL45204A-HL
FL45205A-HL
FL45206A-HL
-
Calibration
GPM
LPM
2-20
8-78
6-60
30-230
8-80
30-300
6-100
20-380
20-130
80-500
25-175
100-675
-
-
SCFM
M3/HR
-
-
-
-
-
-
-
-
-
-
-
-
40-240
70-400