4-11. Summary of Function

4-11-1. Basic Model (Inner Control)
Element A/S Function
Forced Defrosting
Pull Down
Demo function
Error display
4-11-2. Dispenser Model (Front PCB)
1. All the modes are started "LOCK" mode (except "FILTER RESET" mode)
2. Element A/S Function
Forced Defrosting
Reset water filter
Demo function
Pull Down
Error display
EEPROM clear
Ice maker test
Downloaded from Fridge-Manual.com Manuals
INPUT
Each button
CONTENTS
"FRZ.TEMP" + "REF.TEMP" 5 times
"REF.TEMP"+ "FRZ.DOOR" OPEN/CLOSE 5 times
"FRZ.TEMP"+ "FRZ.DOOR" OPEN/CLOSE 5 times
"REF.TEMP"+ "FRZ.TEMP" 5 times
INPUT
Each button
CONTENTS
"FREEZER SET" + "REFRIGERATOR SET" 5 times
Push "RESET WATER FILTER" for 3 seconds
"REFRIGERATOR SET" + "WATER/ICE" 5 times
"REFRIGERATOR SET"+ "FREEZER SET"+ "WATER/ICE"5 times
"FREEZER SET"+ "SUPER FREEZER" 5 times
"WATER/ICE"+ "RESET WATER FILTER" 5times
"WATER/ICE" + "ICE MAKER LOCK" 5 times
CONTROL OBJECT
Resistance of R-sensor Mid ON/OFF Point
CONTROL OBJECT
Resistance of R-sensor Mid ON/OFF Point
25
REMARKS
REMARKS