2-4. Parallel Interface

 Pin Assignment
Pin No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
* The maximum current rating for +5V DC output is 200mA.
(*1) See "Alarm Output Circuit" below.
(*2) See "GPI IN Circuit" in the next page.
(*3) See "GPI OUT Circuit" in the next page.
Alarm Output Circuit
Normally open relay circuit. The circuit behaves as below.
When operating normally:
When a malfunction occurs or the power is off:
Pin 9 is a common pin for both power alarm and fan alarm.
Contact rating is 0.5A@30VDC
アラーム出力
Alarm output
Closed at a
異常時または電源
malfunction or
OFF時にCLOSE
power-off state.
Signal
GND
POW ALARM
Out
FAN ALARM
Out
NC
GPI IN3
GPI IN2
GPI IN1
+5VOUT
Out
COMMON
NC
NC
GPI OUT3
Out
GPI OUT2
Out
GPI OUT1
Out
GND
MBP-100SX側
MBP-100PD side
Relay contact
リレー接点
Relay contact
リレー接点
15-pin D-sub, female
I/O
Description
Signal ground
Power alarm output (*1)
Fan alarm output (*1)
Not used
In
GPI input(*2)
In
GPI input (*2)
In
GPI input (*2)
+5V DC output
Power/Fan alarm output, common (*1)
Not used
Not used
GPI output (*3)
GPI output(*3)
GPI output(*3)
Signal ground
An alarm pin and the common pin are open.
An alarm pin and the common pin are closed.
Max:30V
POW ALARM
FAN ALARM
COMMON