2-5. Parallel Interface
2-5-1. GPI / ALARM
Pin Assignment
Pin No.
1
2
POW ALARM
3
4
5
6
7
8
9
10
11
12
13
14
15
-
* The maximum current rating for +5V output is 200mA.
(*1) See "Alarm Output Circuit" below.
(*2) See "GPI IN Circuit" in the next page.
(*3) See "GPI OUT Circuit" in the next page.
Alarm Output Circuit
A normally open relay circuit that behaves as below.
Under normal operation:
In a malfunction or power-off state:
Pin 9 is a common pin for both the power alarm and fan alarm.
The contact rating is 0.5 A @ 30 VDC.
Signal
I/O
GND
Out
FAN ALARM
Out
NC
GPI IN3
GPI IN2
GPI IN1
+5VOUT
Out
COMMON
NC
NC
GPI OUT3
Out
GPI OUT2
Out
GPI OUT1
Out
GND
-
An alarm pin and the common pin are open.
An alarm pin and the common pin are closed.
13
15-pin D-sub, female
Description
-
Signal ground
Power alarm output (*1)
Fan alarm output (*1)
-
Not used
In
GPI input(*2)
In
GPI input (*2)
In
GPI input (*2)
+5V DC output
-
Power alarm output, common (*1)
-
Not used
-
Not used
GPI output (*3)
GPI output(*3)
GPI output(*3)
-