Parallel Interface; Gpi / Alarm - FOR-A MBP-120SX Operation Manual

Table of Contents

Advertisement

2-5. Parallel Interface

2-5-1. GPI / ALARM

 Pin Assignment
Pin No.
1
2
POW ALARM
3
4
5
6
7
8
9
10
11
12
13
14
15
* The maximum current rating for +5V output is 200mA.
(*1) See "Alarm Output Circuit" below.
(*2) See "GPI IN Circuit" in the next page.
(*3) See "GPI OUT Circuit" in the next page.
Alarm Output Circuit
A normally open relay circuit that behaves as below.
Under normal operation:
In a malfunction or power-off state:
Pin 9 is a common pin for both the power alarm and fan alarm.
The contact rating is 0.5 A @ 30 VDC.
Signal
I/O
GND
Out
FAN ALARM
Out
NC
GPI IN3
GPI IN2
GPI IN1
+5VOUT
Out
COMMON
NC
NC
GPI OUT3
Out
GPI OUT2
Out
GPI OUT1
Out
GND
An alarm pin and the common pin are open.
An alarm pin and the common pin are closed.
13
15-pin D-sub, female
Description
Signal ground
Power alarm output (*1)
Fan alarm output (*1)
Not used
In
GPI input(*2)
In
GPI input (*2)
In
GPI input (*2)
+5V DC output
Power alarm output, common (*1)
Not used
Not used
GPI output (*3)
GPI output(*3)
GPI output(*3)
Signal ground