MAIN BOARD IC1008 TAS3108DCPR (AUDIO DSP)
Pin No.
Pin Name
1
AVSS
2
VR_PLL
3
XTALI
4
XTALO
5
MCLKI
6
MICROCLK_DIV
7
CS0
8
GPIO
9
DVDD_9
10
DVSS_10
11
SDIN1
12
SDIN2
13
SDIN3
14
SDIN4
15
SDA1
16
SCL1
17
SDA2
18
SCL2
19
LRCLK
20
SCLKIN
21
MCLKO
22
SCLKOUT1
23
SCLKOUT2
24
SDOUT4
25
SDOUT3
26
SDOUT2
27
SDOUT1
28
VR_DIG
29
DVSS_29
30
DVDD_30
31
PDN
32
RESET
33
RESERVED_33
34 to 36
PLL0 to PLL2
37
RESERVED_37
38
AVDD
52
I/O
-
Ground terminal (analog system)
-
External capacitor connection terminal for internal regulator
I
System clock input terminal (12.288 MHz)
O
System clock output terminal (12.288 MHz)
I
Master clock signal input terminal
I
Internal microprocessor clock divide control signal input terminal
I
Chip select signal input terminal
O
Interrupt signal output to the system controller
-
Power supply terminal (+3.3V) (digital system)
-
Ground terminal (digital system)
I
Audio data input from the sample rate converter
I
Audio data input from the A/D converter
I
Serial data input terminal
I
Muting on/off control signal input from the system controller
I/O
Two-way I2C data bus with the system controller
I
I2C clock signal input from the system controller
I/O
I2C data bus terminal
Not used
I/O
I2C clock signal bus terminal
I
L/R sampling clock signal input from the sample rate converter
I
Bit clock signal input terminal
Master clock signal output to the D/A converter, sample rate converter and A/D converter
O
(for L-ch/R-ch)
I
Bit clock signal input from the sample rate converter
O
Bit clock signal output to the D/A converter (for L-ch/R-ch)
O
Serial data output terminal
O
Audio data output to the D/A converter (for L-ch/R-ch)
O
Audio data output to the D/A converter (for subwoofer)
O
Audio data output to the D/A converter (for L-ch/R-ch)
-
External capacitor connection terminal for internal regulator
-
Ground terminal (digital system)
-
Power supply terminal (+3.3V) (digital system)
I
Power down signal input terminal
I
Reset signal input from the system controller
-
Connected to the ground
I
PLL control signal input terminal
-
Connected to the ground
-
Power supply terminal (+3.3V) (analog system)
Description
Not used
Not used
Not used
Not used
Not used
Not used
"L": power down
Fixed at "H"
"L": reset
Not used
Not used
"H": muting on