Hide thumbs Also See for N2ition:

Advertisement

Advertisement

Table of Contents
loading

Summary of Contents for Zeagle N2ition

  • Page 3: Table Of Contents

    2. PC Transfer Mode 3. Date and Time Set Mode 4. Dive Mode (Gage Dive Mode) 5. Various Warnings 6. Gage Mode 7. N2iTion Computer Reset 8. Battery Replacement 9. Units of Measurement 20. General Handling 2. Warranty 22. Technical Specifications...
  • Page 5: Introduction

    Introduction Congratulations on your selection of the Zeagle N2iTion Dive Computer. The N2iTion is a compact and sophisticated dive instrument that will give you a reliable, trouble free performance, dive after dive. Please read and understand this manual completely before using your new Zeagle N2iTion Dive Computer.
  • Page 6 Use of the N2iTion in conjunction with Enriched Air Nitrox (EANx) further requires that the diver be trained and certified for Nitrox diving.
  • Page 7 WARNINGS The N2iTion is designed to be used by only one diver at a time. Divers should not share a single N2iTion, or any dive computer, on the same dive. Additionally, no diver should lend his or her N2iTion to anyone else until it calculates that no measurable residual nitrogen remains after previous dives, and displays neither the “Desaturation Time”...
  • Page 8: Accessing Display Modes

    Surface Mode. To access other modes you may need to push one of the three large, grey buttons on the N2iTion’s face. These are the A (LEFT), B (MODE), and C (RIGHT) buttons. (Fig. 1) You will find these buttons easy to use. In some instances you may need only press a button once and release it to achieve the desired result.
  • Page 9: Time Mode

    5. Time Mode Time mode is the N2iTion’s default mode. In this mode the screen displays a minimum of the current date and time of day. Within 24 hours of surfacing from a dive, the N2iTion will display additional information while in Time Mode.
  • Page 10: Battery Indicator

    PC transfer and dive mode. Important! Once the battery indicator is blinking or ON you must return the N2iTion to your local authorized Zeagle dealer for battery replacement, or replace the battery yourself following the procedure outlined later in this manual. Before replacing your N2iTion’s battery, be sure to upload or copy all dive log...
  • Page 11: Altitude Setting

    Time Mode and Plan Mode (In Dive Log Mode the rank of the dive is displayed.) Warning The N2iTion is not intended for use at altitudes above 19680 ft (6000 m). Diving at high altitudes carries an increased risk of decompression sickness.
  • Page 12 Below are the Altitude Setting Icons for the rank of 0,1,2,3. If the altitude exceeds 19680 feet the icon will blink and the Err icon will be displayed. (Fig. 5) Altitude Rank Fig. 5 If the Altitude exceeds 19680 feet (6000 meters) the display shown below will appear.
  • Page 13: Dive Set Mode And Gage Dive Set Mode

    Operation of Buttons During Time Mode Prior to a dive The letters correspond to the buttons of the N2iTion shown in figure 1. • A (LEFT): EL back light is on from 4-5 seconds. • B (MODE): Press this button to move to dive set mode.
  • Page 14 Maximum Depth Alarm Dive Time Alarm Fig. 11 Fig. 10 In Dive Set mode the following information is displayed. • Fraction of oxygen (FO ): (Fig. 8) MIX1 setting range: Fraction of oxygen 21-50% MIX2 setting range: Fraction of oxygen 21-99% •...
  • Page 15 Caution The “--” display: The setting changes to this display automatically at 24:00 on the day the MIX value was set except when the setting is Air equals 21%). If the user forgets to set the FO an audible and flashing alarm is generated when the computer moves to Dive mode.
  • Page 16: Dive Plan Mode 4

    9. Dive Plan Mode To enter Dive plan mode from Time mode press the B (MODE) button twice. Note: This mode cannot be entered while using Gage Mode. Altitude Rank NDL (No decompression Limit Time Depth Rank Don’t Fly Icon Surface Time PGT Graph OLI Graph...
  • Page 17 Nitrox Icon: This Icon is ON when NITROX has been set for MIX1 or MIX2. It blinks if the MIX1 and MIX2 setting are using the default setting. The FO must be set prior to diving with the N2iTion. • Don’t Fly Icon: While the computer calculates desaturation time, this icon is turned on in Time mode.
  • Page 18: Dive Log Mode 6

    10. Dive Log Mode To enter Dive log Mode from Time Mode press the B button three times. Display 1 Dive Date Dive Time Dive Number Dive End Time Dive Start Time Fig. 13 Log Number Fraction of Oxygen Display 2 Water Temperature User Safety Factor OLI Graph...
  • Page 19 Description of the Dive Log functions The Dive log mode records various data during a dive when the dive depth is at least 5 feet (1.5m) and the dive time is at least 3 minutes. Data is recorded during each successive dive, and the log data storage capacity is about 30 hours of dive time, or up to 60 log data entries.
  • Page 20 • Average Depth: this is the average water depth during the dive. If the depth is over 328 ft. (99.9m), the display is ‘---’. In Gage mode if depth is over 656 ft. (199.9m), the display is ‘---’. (Fig. 14) •...
  • Page 21 warning OLI warning Fig. 21 Fig. 20 OLI bar graph blink icon blink The Gage Dive Log Mode provides functions for reviewing information recorded during a dive. It functions the same as dive log mode when the dive depth is at least 5 ft. (1.5m) and the dive time is at least 3 minutes. The gage icon will be displayed and it will show that the computer was used in gage mode.
  • Page 22 Operation of buttons during Log mode • A: Press this button to change the log number. (60-1 —>60-2—> —>2-1 —>2-2—> 1-1 —>1-2) • A: Press and hold this button to change log number using fast scrolling. • B: Press this button to move to Dive Profile Mode. •...
  • Page 23: Dive Profile Mode

    11. Dive Profile Mode Profile depth No data Dive time Dive date Fig. 23 Fig. 24 Fraction of Oxygen Sea/Fresh icon Mode Log number Description of the Dive Profile mode. Dive log mode provides functions for recording various data during a dive when the dive depth is at least 5 feet (1.5m) and the dive time is at least 3 minutes.
  • Page 24 Operation of Buttons during Profile mode. From Time Mode press the B button four times to enter Profile Mode. • Auto count up dive time: The display automatically increases the dive time. • A: Press and hold this button to stop the auto rank increment function for profile data.
  • Page 25: Pc Transfer Mode

    12. PC Transfer Mode If surface time is less than 10 minutes after a dive, and there is no log and profile data, the computer will move to Time Mode. Fig. 25 Mode Description of display during PC Transfer Mode •...
  • Page 26: Date And Time Set Mode

    13. Date and Time Set Mode Note: If surface interval time is less than 10 minutes after a dive, the computer will not enter this mode. Current Time Year Current Date Fig. 26 Blinking icons are show within a square Description of Display during Date and Time set mode (Fig.
  • Page 27: Dive Mode (Gage Dive Mode)

    14. Dive Mode (Gage Dive Mode) The N2iTion will automatically enter Dive Mode when the D (TOP) buttons come in contact with water. Safety Stop Non-decompression Current Depth Safety Stop time OLI Graph PGT graph Dive time Fig. 28 Ascent rate indicator Fig.
  • Page 28 Decompression DECO Stop icon Decompression stop depth Current depth Decompression stop time PGT Graph OLI graph Total ascent time Pressure of Oxygen PO Fig. 30 Procedure to change the Nitrox mix during a dive Press “A” button for 5 seconds Hold Button C DECO Stop icon Maximum depth...
  • Page 29 The N2iTion will switch automatically to TIME mode after 48 hours have elapsed. This information is recorded in the dive log. The N2iTion can only switch to log, profile, or PC transfer mode while the calculations have stopped.
  • Page 30 MIX2, or if it was MIX2 the display switches to MIX 1. If the PO of the new mix is equal to or more than 1.6 the N2iTion will not allow the mix to be changed. Also, if the MIX2 is ‘ -- ’%, it will not change.
  • Page 31 Failure to do so may mean that your N2iTion will be unable to accurately monitor your exposure to nitrogen and oxygen, and lead to decompression illness (DCI) or CNS Oxygen Toxicity, conditions that can cause serious personal injury or death.
  • Page 32 • Nitrox Icon: This Icon is ON when NITROX has been used for MIX1 or MIX2. It blinks if the MIX1 and MIX2 setting is the default setting. (Fig. 31) • Gage Mode Icon: This icon is diplayed during Gage Mode. (Fig. 29) •...
  • Page 33: Various Warnings

    • Ascent rate warning: If a diver exceeds the recommended ascent rate according to the depth, the N2iTion informs the diver with the display and an audible alarm. The warning will continue until you slow your ascent rate or until you reach a depth of 5 ft/1.5m. This information is recorded in the dive log.
  • Page 34 Decompression stop warning violation Fig. 36 Oxygen Limit Indicator warning: When the OLI graph reaches 7 or 8 bars, the N2iTion responds with a flashing display and an audible alarm. There are two types of warnings, as described below. (Fig. 37) Graph value equals 7 bars: The computer informs the diver with the display and the alarm.
  • Page 35 warning: (Fig. 38) The Pressure of oxygen (PO ) value is determined based on the set oxygen ratio and the current depth. When the PO value exceeds a certain value, the information is recorded in the dive log when the PO warning occurs once.
  • Page 36 And EL back light is on from 4-5 seconds. • Ιn less than 5 feet (1.5 m) of water the N2iTion moves to time mode. Decompression/Decompression stop violation (Fig. 30,36) • A:(LEFT) Press this button for 3-4 seconds to change the MIX . The EL back light is on from 4-5 seconds.
  • Page 37 FO value. The EL back light will come on for 4-5 seconds. • At a depth less than 5 feet (1.5 m) the water detection button switches OFF and the N2iTion moves to a lock condition.
  • Page 38 Out of measurement range lock In this mode the N2iTion is locked until 48 hours have elapsed. All display segments blink during time mode. The computer can’t move to dive plan mode, dive set mode, time set mode. • A:(LEFT) Press this button to select the place you want to change. In time mode, display, EL back light is on from 4-5 seconds.
  • Page 39: Gage Mode

    16. Gage Mode The only functions that can be performed by the computer in this mode are the depth calculation, water temperature measurement, and dive time measurement functions. Calculation functions (such as calculation of PGT, OLI etc.) are not performed. If you dive in this mode for 3 minutes or longer, this information will be recorded in the dive log and profile mode.
  • Page 40 When diving in the gage mode, the Gage Icon is displayed while in dive log mode. The PC transfer mode and time set mode operate normally. Operation of Buttons during Gage mode B:(MODE) This button is used to select the mode. Time mode—>Dive set mode—>Dive log mode—>Dive profile mode—>PC Transfer mode—>Time set mode—>Time mode—>...
  • Page 41: N2Ition Computer Reset

    17. N2iTion Computer Reset All settings can be set to manufacturer default values by using the computer reset button. This button is located on the back of the computer near the bat- tery compartment door. To reset the computer simply press the button. All data regarding nitrogen absorption, desaturation, as well as the time and date will be erased.
  • Page 42: Units Of Measurement

    ZEAGLE or its authorized dealers. Unauthorized disassembly will violate the warranty. If the N2iTion does not appear to be functioning properly, in any manner, do not use it to dive. Return it to your authorized ZEAGLE dealer for repair. Rinse the N2iTion thoroughly in fresh water following every dive.
  • Page 43: Warranty

    (2) years from date of original purchase. Under this limited warranty, ZEAGLE will either repair or replace, at its sole option, any original equipment or parts that fail to perform as intended.
  • Page 44 Zeagle expressly limits any and all dive computer warranties, expressed or implied, to the two year term as set forth above. All remedies are waived unless claim is made within the applicable twenty- four (24) month period.
  • Page 45: Technical Specifications

    Battery life: about 3 years (uses battery CR2032) under conditions as follows: The computer is used for 50 one-hour dives in a year, with the alarm sounding for 10 seconds per a dive. 7) Algorithm • The N2iTion uses a modified Swiss model, 12 compartment Algorithm by Randy Bohrer...