TECHNICAL DATA

2.1 TECHNICAL DATA
Thermal power
(Family 2)
Natural gas
Electrical supply
Motor
Capacitor
Ignition transformer
Absorbed electrical power
(1) Reference conditions: Temp. 20°C - Barometric pressure 1013 mbar – Altitude 0 m above sea level.
For gas family 3 (LPG) ask for separate kit.
COUNTRY
GAS CATEGORY
II2Er3P

2.2 OVERALL DIMENSIONS

305
33
D4201
2.3 WORKING FIELD
1.6
1.4
1.2
1.0
0.8
0.6
0.4
0.2
0
40
D5256
40,000
2721
(1)
42 – 116 kW
Net heat value: 8 – 12 kWh/Nm
Pressure: min. 16 mbar
Single phase, 230 V
230V / 0.7 A
2 µF
Primary
230V / 1.8 A
0.13 kW
FR
DK - AT - GR - SE - IT
II2H3B/P
Burner
36
Combustion head extension, supplied separately.
(as EN 676)
50
60
70
50,000
60,000
-
36,000 – 100,000 kcal/h
3
7,000 – 10,340 kcal/Nm
-
-
max. 100 mbar
~
±
10%
50Hz
-
Secondary 8 kV / 30 mA
LU
DE
II2E3B/P
II2ELL3B/P
110
346
170
61
80
90
100
70,000
80,000
GB
2
3
GB - IE - ES - PT
II2H3P
Flange
185
130
110
120
kcal/h
90,000
100,000
Thermal power
NL
II2L3B/P
kW