Connection Of The Electric Cables - Mitsubishi Electric PLK-G1010 Technical Manual

Electronic pattern sewing machine
Table of Contents

Advertisement

3-10. Connection of the electric cables

(1) Please make sure to ground the place where there is a
shock and/or malfunction.
(1) Connect the machine head and the control box with cables as shown on the figure.
(2) Hold the dangling cables under the table with accessory tie holders (MB60A0420) and cord ties
(MB60A0201). At this time, please check whether the cables are not pulled when tilting the sewing
machine.
<2>
<1>
<3>
<4>
CON A
CON E
CON F
CON G
CON H
CON J
CAUTION
<5>
<7>
<6>
CON B
CON C
CON D
CON K
- 7 -
mark. Failure to do so may cause electric
<1>: Solenoid cable
<2>: Solenoid power cable
<3>: Spindle encoder cable
<4>: Spindle motor cable
<5>: X-Y spindle encoder cable
<6>: X-Y spindle motor cable
<7>: P-F spindle motor cable
CON A: Operation panel
CON B: Power supply
CON C: Various solenoid DC power
CON D: Spindle motor
CON E: Various solenoid
CON F: Spindle encoder
CON G: X-Y spindle encoder
CON H: Foot switch
CON J: X-Y spindle stepping motor
CON K: P-F spindle stepping motor