Hide thumbs Also See for AP1 Series:
Table of Contents

Advertisement

Available languages

Available languages

AP1 & RP SERIES
PROF
GE
AL
HOOD
STYLE
Page
1
To register this
product visit:
www.broan.com
FOR DOMESTIC
WAR.I.G
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR IN-
JURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufac-
turer. If you have questions, contact the manufacturer at the
address or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service
panel. Lock or tag service panel to prevent power from being
switched on accidentally.
3. Installation work and electrical wiring (including switch loca-
tion) must be done by a qualified person(s) in accordance
with all applicable codes and standards,
including fire-rated
construction.
4. Provide sufficient air for proper combustion and exhausting
of gases through the flue (chimney)
d fuel burning equip-
ment to prevent backdrafting.
Follow the combustion equip-
ment standards
such as those published
by the National
Fire Protection Association
(NFPA), the American Society
for Heating, Refrigeration
and Air Conditioning
Engineers
(ASHRAE), and local codes.
5. This product may have sharp edges. Be careful to avoid cuts
and abrasions during installation and cleaning.
6. When cutting or drilling into walt or ceiling, do not damage
electrical wiring and other hidden utilities.
7. Ducted fans must always be vented to the outdoors.
8. Use only metal ductwork.
9. As an alternative, this product may be installed with the UL-
approved cord kit designated
for the product, following in-
structions packed with the cord kit.
10. This unit must be grounded.
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
1. Never
leave surface
units unattended
at high settings.
Boitovers cause smoking and greasy spitlovers that may ig-
nite. Heat oils slowly on low or medium settings.
2. Always turn hood ON when cooking at high heat or when
flambeing food (i.e. Crepes Suzette, Cherries Jubilee, Pep-
percorn Beef Ftambe).
3. Clean ventilating fans frequently.
Grease should not be al-
lowed to accumulate on fan or filter.
4. Use proper pan size. Always use cookware appropriate for
the size of the surface element.
COOKING
ONLY
TO REDUCE THE RISK OF INJURY TO PERSONS iN THE
EVENT OF A RANGE TOP GREASE FIRE, OBSERVE
THE
FOLLOWING:*
1. SMOTHER
FLAMES with a close-fitting
lid, cookie sheet,
or metal tray, then turn off the burner. BE CAREFUL
TO
PREVENT BURNS. If the flames do not go out immediately,
EVACUATE AND CALL THE FIRE DEPARTMENT.
2. NEVER PICK UPA FLAMING PAN --You
may be burned or
spread the fire.
3. DO NOT USE WATER, including wet dishcloths
or towels
- violent steam explosion will result.
4. Use an extinguisher ONLY if:
A. You know you have a Class ABC extinguisher
and you
already know how to operate it.
B. The fire is small and contained in the area where it started.
C. The fire department is being called.
D. You can fight the fire with your back to an exit.
* Based on "Kitchen Fire Safety Tips" published by NFPA.
CAUTION
1. For general ventilating use only. Do not use to exhaust haz-
ardous or explosive materials and vapors.
2. For best capture of cooking impurities, range hood should be
mounted so that the bottom of the hood is 18"-24" above the
cooking surface.
3. Read specification
label on product for information and re-
quirements.
_
These instructions are for ducted installations only.
If hood is to be installed non-ducted:
Purchase a non-ducted filter kit from your local distributor or
retailer. (Available forAP1 & RP2 Series hoods only.) Follow
instructions included with the non-ducted kit.
Homeowner:
Installer: Leavethis manual with the homeowner.
Cleaning, Maintenance and Operating instructions on page 2.

Advertisement

Table of Contents
loading

Summary of Contents for Broan AP1 Series

  • Page 1 AP1 & RP SERIES Page PROF STYLE To register this HOOD product visit: www.broan.com FOR DOMESTIC COOKING ONLY WAR.I.G TO REDUCE THE RISK OF INJURY TO PERSONS iN THE TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR IN- JURY TO PERSONS, OBSERVE THE FOLLOWING:...
  • Page 2: Cleaning And Maintenance

    AP1 & RP SERIES Page CLEANING & MAINTENANCE AP SERIES HOOD Operate the hood as follows: For performance, appearance, and health reasons, clean filter, fan and grease-laden surfaces. Use only a clean cloth and mild detergent solution on stainless and painted surfaces. Clean all- ©...
  • Page 3: Prepare The Hood

    AP1 & RP SERIES Page PREPARE THE HOOD proper Use the diagram below, for placement of ductwork and electrical cutout in cabinet or wall. For a non-ducted installation, DO NOT cut a duct access hole. 31/4"X 10" HOOD MOUNTING SCREWS (4) VERTICAL DUCTING _J===...
  • Page 4: Connect The Wiring

    AP1 & RP SERIES Page CONNECT THE WIRING DAMPER / DUCT CONNECTOR VERTICALDUCT KNOCKOUT GREEN GROUND SCREW HOUSE POWER CABLE range Connect House Power Cable to hood wiring - BLACK to BLACK, WHITE to WHITE, and GREEN or HORIZONTAL DUCT BARE WIRE to GREEN Ground Screw.
  • Page 5: Warranty

    OR IMPLIED,INCLUDING, B UT NOT LIMITEDTO, IMPLIEDWARRANTIESOF PVCFoam 99500323 MERCHANTABILITY ORFITNESSFORA PARTICULARPURPOSE, 98010342 Ring, Inlet Duringthisone-yearperiod,Broan will, atits option,repairor replace, w ithoutcharge, HexNut3/8-32 any productor partwhich is foundto be defectiveunder normaluse and service, 99260491 THISWARRANTYDOESNOT EXTENDTO FLUORESCENTLAMPSTARTERS HexNut 15/32-32 99260470 AND TUBES.This warrantydoes not cover (a) normalmaintenanceand service...
  • Page 6 SERIES APt ET RP Page OTTE I IE Pour enregistrer ¢e STYLE PROF produit, visitez: WWW. broan.corn POUR USAGE DOMESTIQUE SEULEMENT AVERTISSEMENT , AVERTISSEMENT OBSERVEZ LES CONSIGNES SUIVANTES DE MANI€:RE AFJN DE RCrDUIRE RISQUES D'INCENDIE, DE CHOC ri=LECTRIQUE BLESSURES CORPORELLES,...
  • Page 7: Nettoyage Et Entretien

    (3-1/4 X 10 po.) Pour evacuation verticale) Pour utitiser la hotte, faites comme suit : SOFFITE _ C,&,BLAGE ELECTRIQUE BROAN Haut ou arriere de la hotte) INTERRUPTEUR DU VENTILATEUR Cet interrupteur a trois positions met la hotte en MARCHE, sur ARRET CAPUCHON...
  • Page 8 SERIES APt ET RP Page PRI=PARATION DE LA HOTTE ik I'aide des diagrammes ci-dessous, determinez I'emplacement exact des coupes a effectuer pour le conduit et le fil d'alimentation electrique dans I'armoire ou lemur. Pour une installation sans conduit, NE PAS decouper de trou pour le conduit. 8,3 X 25,4 CM (3-1/4 X 10 PO.) CONDUIT VERTICAL (4) VIS DE MONTAGE...
  • Page 9: Installation De La Hotte

    SERIES APt ET RP Page RACCORD DU C.&,BLAGE CLAPET/ RACCORD CONDUIT OUVERTURE PRI_AMORCI_E VERTICALE VIS VERTE DE MISEA LA TERRE Connectez le fil d'alimentation _lectrique a la hotte en raccor- dant le fil NOIR au fil NOIR, le fil BLANC au fil BLANC, et le fil OUVERTURE PREAMORCI_E VERT ou le FIL D#NUDI_ a la vis VERTE de raise _ la terre.
  • Page 10: Pieces De Rechange

    GARANTIE LJMITEE D'UN AN DE BROAN 99020143 Roue a ailettes, sens antihoraire Broan garantit _ I'acheteur consommateur original de ses produits quils sont exempts de 99400055 Manchon, butee fendue vice de materiaux ou de fabrication pour une periode d'un an _ compter de la date d'achat...
  • Page 11 SERIE AP1 Y RP P#gina Para registrar este PROFESIONAL ESTILO producto visite: WWW. broari.con3 SOLAMENTE PARA COCINAR EN CASA ADVE.TE.CIA ADVE.TE.CIA PARA P,EDUCIP, EL P,IESGO DE INCENDIOS, DESCAP,GAS PARA P,EDUCIR RIESGO LESIONES EL#CTP,ICAS O LESIONES PEP,SONALES, OBSERVE PERSONAS EN CASO DE UN INCENDIO PRODUCIDO POP`...
  • Page 12: Limpieza Y Mantenimiento

    SERIE AP1 Y RP P4gina LIMPIEZA Y MANTENIMIENTO CAMPANA SERIE AP Para hacer funcionar la campana, haga to siguiente: Por motJvos de desempeSo, apariencia y salud, IJmpie el filtro, el ventilador y las superficies que tengan grasa. Utilice t_nicamente trapo limpio y una soluci6n de detergente suave en superficies de acero 0 •...
  • Page 13 SERIE AP1 Y RP P4gina GuieseporeJdJagramacorrespondiente(acontinuaci6n) para PREPARE LA CAMPANA colocar Jos conductos y hacer el corte exacto para la conexi6n eJectrica en el gabinete o en Ja pared. Para instaJaciones sistemas sin conductos, NO haga ningQn orificio de acceso para conducto.
  • Page 14: Conecte El Cableado

    SERIE AP1 Y RP PDgina CONECTE EL CABLEADO CONECTOR DEL II REGULADOR DE i TIRO/CONDUCTO_ AGUJERO CIEGO DEL CONDUCTO VERTICAL TORNILLO VERDE DE CONEXION ATIERRA CABLE DE LA CASA Conecte el cable el_ctrico de la casa al cableado de la cam- _"...
  • Page 15: Piezas De Repuesto

    99400055 Buje de cierreHeyco 99500323 Espumade PVC Durante el periodo de un afio, y a su propio criterio, Broan repararao reemplazar& sin costo algano cuaiqaier producto o pieza que se encuentredefectuosa bajo condicionesnormales de 98010342 Arc, entrada servicio y uso.
  • Page 16 ® SERIE AP1 Y RP P_gina 99044040E...

This manual is also suitable for:

Rp series

Table of Contents