This task invokes the SMIT Update Software by Fix (APAR) task. The task allows the input device and
APARs to be selected. You can install any APAR using this task.

Update System or Service Processor Flash

Attention:
If the system is running on a logically partitioned system, ask the customer or system
administrator if a service partition has been designated.
v If a service partition has been designated, ask the customer or system administrator to shut down all of
the partitions except the one with service authority. The firmware update can then be done using the
service aid or the AIX command line in that partition.
v If a service partition has not been designated, the system must be shut down. If the firmware update
image is available on backup diskettes, the firmware update can then be done from the service
processor menus as a privileged user. If the firmware update image is in a file on the system, reboot the
system in a full system partition and use the following normal firmware update procedures.
If the system is already in a full system partition, use the following normal firmware update procedures.
This selection updates the system or service processor flash.
Look for additional update and recovery instructions with the update kit. You need to know the fully
qualified path and file name of the flash update image file provided in the kit. If the update image file is on
a diskette, the service aid can list the files on the diskette for selection. The diskette must be a valid
backup format diskette.
Refer to the update instructions with the kit, or the service guide for the system unit to determine the
current level of the system unit or service processor flash memory.
When this service aid is run from online diagnostics, the flash update image file is copied to the /var file
system. It is recommended that the source of the microcode that you want to download be put into the
/etc/microcode directory on the system. If there is not enough space in the /var file system for the new
flash update image file, an error is reported. If this error occurs, exit the service aid, increase the size of
the /var file system, and retry the service aid. After the file is copied, a screen requests confirmation
before continuing with the flash update. When you continue the update flash, the system reboots using the
shutdown -u command. The system does not return to the diagnostics, and the current flash image is not
saved. After the reboot, you can remove the /var/update_flash_image file.
When this service aid is run from standalone diagnostics, the flash update image file is copied to the file
system from diskette or from the NIM server. Using a diskette, the user must provide the image on backup
format diskette because the user does not have access to remote file systems or any other files that are
on the system. If using the NIM server, the microcode image must first be copied onto the NIM server in
the /usr/lib/microcode directory pointed to the NIM SPOT (from which you plan to have the NIM client
boot standalone diagnostics) prior to performing the NIM boot of diagnostics. Next, a NIM check operation
must be run on the SPOT containing the microcode image on the NIM server. After performing the NIM
boot of diagnostics one can use this service aid to update the microcode from the NIM server by choosing
the /usr/lib/microcode directory when prompted for the source of the microcode that you want to update.
If not enough space is available, an error is reported, stating additional system memory is needed. After
the file is copied, a screen requests confirmation before continuing with the flash update. When you
continue with the update, the system reboots using the reboot -u command. You may receive a Caution:
some process(es) wouldn't die message during the reboot process, you can ignore this message. The
current flash image is not saved.
You can use the update_flash command in place of this service aid. The command is located in the
/usr/lpp/diagnostics/bin directory. The command syntax is as follows: