Test Procedure - Nokia RM-484 Service Manual

Table of Contents

Advertisement

Required equipment
The following equipment is needed for the tests:
• Oscilloscope
• Function generator (sine waveform)
• Current probe (Internal handsfree DPMA output measurement)
• Phoenix service software
• Battery voltage 3.7V
• Sound source (laptop speaker or B&K type 4231 calibrator)

Test procedure

Audio can be tested using the Phoenix audio routings option. Three different audio loop paths can be
activated:
• External microphone to Internal earpiece
• External microphone to Internal handsfree speaker
• Internal microphone to External earpiece
Each audio loop sets routing from the specified input to the specified output enabling a quick in-out test.
Loop path gains are fixed and they cannot be changed using Phoenix. Correct pins and signals for each test
are presented in the following table.
Phoenix audio loop tests and test results
The results presented in the table apply when no accessory is connected and battery voltage is set to 3.7V.
Earpiece, internal microphone and speaker are in place during measurement. Applying a headset accessory
during measurement causes a significant drop in measured quantities.
The gain values presented in the table apply for a differential output vs. single-ended/differential input.
Loop test
Input
terminal
External
HS_MIC &
Mic to
GND
External
Earpiece
External
HS_MIC &
Mic to
GND
Internal
Earpiece
External
HS_MIC &
Mic to
GND
Internal
handsfre
e
Page 3 –40
Output
Path gain
terminal
[dB]
(fixed)
HS_EAR_L
-8.6
& GND
HS_EAR_R
& GND
EarP &
-10
GND
EarN &
GND
J2103 &
-6
J2104
J2101 &
J2102
COMPANY CONFIDENTIAL
Copyright © 2009 Nokia. All rights reserved.
Input
Outout
voltage
voltage
[mVp-p]
[mVp-p]
1000
367
1000
310
1000
RM-484; RM-485; RM-486
BB Troubleshooting
Output DC
Output
level [V]
current
[mA]
1.2
NA
1.2
NA
Issue 1

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

Rm-485Rm-486N86 8mpL3L4