3
Electrical data
Representative Unit Combination
Indoor Unit
Outdoor Unit
FTXS20G2V1B
RXS20G2V1B
3
S
IMBOLS
MCA
:
Min. circuit amps.
MFA
:
Max. Fuse Amps.
RLA
:
Rated Load Amps.
OFM
:
Outdoor Fan Motor
IFM
:
Indoor Fan Motor
FLA
:
Full Load Amps
W
:
Fan Motor Rated Output
RHz
:
Rated Operated Frequency
24
3
Representative Unit Combination
Indoor Unit
Outdoor Unit
FTXS25G2V1B
RXS25G2V1B
S
IMBOLS
MCA
:
Min. circuit amps.
MFA
:
Max. Fuse Amps.
RLA
:
Rated Load Amps.
OFM
:
Outdoor Fan Motor
IFM
:
Indoor Fan Motor
FLA
:
Full Load Amps
W
:
Fan Motor Rated Output
RHz
:
Rated Operated Frequency
8
• Outdoor Units • R-410A • RXS-G2V1B
Power Supply
Hz-Volts
Voltage Range
MCA
Max. 50Hz 264V
50 - 220
9.75
Min. 50Hz 198V
(A)
(A)
(A)
(A)
(W)
(Hz)
Power Supply
Hz-Volts
Voltage Range
MCA
Max. 50Hz 264V
50 - 230
9.75
Min. 50Hz 198V
(A)
(A)
(A)
(A)
(W)
(Hz)
• Split Sky Air • Outdoor Units
Comp
MFA
RHz
RLA
2.3
10
34
2.2
N
OTES
1
RLA is based on the following conditions.
Indoor temp. 27C°DB/19°CWB
Outdoor Temp. 35°CDB.
2
Maximum allowable voltage variation between phases is 2%.
3
Select wire size based on the lager value of MCA.
4
Instead of fuse, use circuit breaker.
Comp
MFA
RHz
RLA
2.7
10
34
2.5
N
OTES
1
RLA is based on the following conditions.
Indoor temp. 27C°DB/19°CWB
Outdoor Temp. 35°CDB.
2
Maximum allowable voltage variation between phases is 2%.
3
Select wire size based on the lager value of MCA.
4
Instead of fuse, use circuit breaker.
OFM
IFM
W
FLA
W
50
0.23
23
3D055006B
OFM
IFM
W
FLA
W
50
0.23
23
3D055008B
FLA
0.15
FLA
0.15