Water Supply And Drain Connections - Hoshizaki FM-150KE Installation Manual

Self-contained ice maker
Hide thumbs Also See for FM-150KE:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
ENGLISH
For the U.K. and the Republic of Ireland only
* The wires in the mains lead are coloured in accordance with the following code:
Green & Yellow = Earth
Blue = Neutral
Brown = Live
As the colours of the wire in the mains lead of this appliance may not correspond with the coloured markings identifying the
terminals in your plug, proceed as follows:
The wire which is coloured Green-and-Yellow must be connected to the terminal in the plug which is marked with the letter
E or by the symbol
terminal which is marked with the letter N or coloured Black. The wire which is coloured Brown must be connected to the
terminal which is marked with the letter L or coloured Red.
* Should the socket outlets in the installation site not be suitable for the plug supplied with your product, the plug must be
removed (cut off if it is moulded on plug) and an appropriate plug fitted.
If the non-rewirable plug has been cut from the power supply cord, it must be disposed of. There should be no attempt to
reuse it. Inserting such a plug into a socket elsewhere presents a serious risk of electrical shock.
* The non-rewirable plug must never be used without a fuse cover being fitted.
The correct replacement for the detachable fuse cover is identifiable from the manufacturer's reference number stamped on
the plug.
Supply of replacement fuse covers can be obtained from Hoshizaki Parts/Service Centres.
Fuses should be rated at 13A and approved to BS 1362.

7. WATER SUPPLY AND DRAIN CONNECTIONS

* The connections to the mains water supply must be made in accordance with the countries' current
requirements of the Water Supply or Water Fittings Regulations.
* Icemaking water must be potable water. Where scaling can be caused by water quality, installation
of an external filter or softener is recommended. Contact your local water treatment professional or
Hoshizaki service agent.
* Water supply pressure should be minimum 0.05 MPa (0.5 bar) and maximum 0.8 MPa (8 bar). If
the pressure exceeds 0.8 MPa (8 bar), use a proper pressure reducing valve. Do NOT throttle back
the supply tap.
* A plumbing permit and services of a licensed plumber may be required
in some areas.
* The icemaker drain is gravity flow, so ensure drain pipe has an
adequate pitch or fall.
* Drain lines should not be piped directly to the sewer system. A vertical
air gap of a minimum of 5 cm should be between the end of the drain
pipes from the icemaker and the floor drain.
* Water supply connection is intended to be made by means of a pipe,
not a hose set.
or coloured Green or Green-and-Yellow. The wire which is coloured Blue must be connected to the
Connect to potable water supply only.
WARNING
Water Supply Line
Shut-off Valve
Drain Valve
4
5cm air gap
Floor
Drain
Water Supply
Inlet G3/4
Drain Outlet R3/4