mA: indicates the maximum current (in mA) absorbed by the brew unit in motion. The value must
not exceed 300 mA
Encoder Pulses Home-Work: indicate the number of encoder pulses from Home to Work posi-
tion or vice versa. Move the brew unit from Home to work or vice versa and the measured value
must bein the range [2000 – 2100].
H/W: Becomes active when the Brew Unit reach HOME or WORK position
Pres: Becomes active if the Brew Unit is present in machine
DDr: Becomes active if the Dreg Drawer is present in machine
Door: Becomes active if the Frontal Door is closed
Hydaulic Circuit
This page allow to test the functionality of hydraulic circuit:
Boliler
temperature (°C)
The meaning of the sectors are the following:
Command:
Boiler: when pressed activate/deactivate the boiler if the temperature is less than 90°C
Pump: when pressed activate/deactivate the pump
Ev S: when pressed activate/deactivate the Steam/Water electrovalve (24V Dc)
Ev D: when pressed activate/deactivate the discharge electrovalve (24V Dc)
Info:
p/s: indicate the current number of water fl ow expressed in pulses/sec. When is activated the
pump and one electrovalve the value measured must be equal to or greater than 10 p/s.
Tank: Becomes active when the water into tank reach sensor level
DripTray: Becomes active when the water into drip tray reach sensor level
Frequency: indicate the frequency of mains voltage supply
Boiler Temperature: indicate the boiler temperature in °C
Downloaded from
www.Manualslib.com
Press UP (
HYDR
Boiler
Pump
25
Press UP (
manuals search engine
): go to next page
CIRCUIT
Ev S
p/s
Ev D
^
Tank
DTray
): go to next page
05 TROUBLESHOOTING
0
^
Mains voltage
50 Hz
supply frequency
Page
11
/ 18

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Granbaristo

Table of Contents