Saeco GranBaristo Avanti Service Manual page 37

Table of Contents

Advertisement

GRAN BARISTO
Activation of loads
In Test Mode all loads are initially disabled.
To activate a load press the corresponding button on keyboard, to deactivate press again the
same button.
Other conditions for which a load may be switched off automatically without key presses are:
· If it is defi ned a working cycle, when this cycle ends (such as the grinder or brew unit)
· The achievement of 90°C for boiler
SoftwareVersion
This is the fi rst window of Factory Test Mode. It show the version of CPU software and CPU
bootloader version, the PWR software and PWR bootloader version and is possible to activate or
deactivate the POff feature and Debug info.
Press OK ( ) button to modify one of the following feature:
Debug msg: if enabled (colored box), only for next startup, allows the visualization of the follow-
ing debug info on display in Ready state:
P Off: if enabled (colored box), allows the machine to enter in standby mode immediately after
powering ON from the main switch.
Make sure that the function P Off is turned ON and the Debug msg is turned OFF.
Downloaded from
www.Manualslib.com
Navigation in Test Mode
CPU SW
^
BootC
POWER SW
Grinder Time
Encoder Pulses
Aroma 1
Home Work
(msec)
About Last Cycle
Grinder Time
Aroma 2
(msec)
Grinder Time
Aroma 3
(msec)
Encoder Pulses
HOME to
Pod Pressure About
Last Cycle
Press UP (
manuals search engine
xx.yy.zz
Debug msg
P Off
^
V.jj
BootP
uu.vv.ww
Encoder Dreg Counter:
4000 ->dreg drawer empty
0-> dreg drawer full
Target Encoder Pulses
from HOME to Pod Pressure
about last Cycle
): go to next page
05 TROUBLESHOOTING
^
V.kk
Grinder Time
Aroma 4
(msec)
Grinder Time
Aroma 5
(msec)
Grinder Time
Aroma 6
(msec)
09
Page
/ 18

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Granbaristo

Table of Contents