4)
Remove the rear cabinet cover.
Remove the screw and then remove the rear cabinet cover.
5)
Cut out a part of the rear cabinet cover.
Cut out the cut-out portion of the rear cabinet cover with nip-
pers or the like. (Be careful about the orientation of the nippers
so that the cross section is flat.)
6)
Place the ADF on the copier.
Gently place the ADF on the document glass as shown in the
illustration. At this time, be careful not to damage the original
scanning section and the OC mat.
OC mat
Original scanning
section
MR-2019/2018/MY-1034 UNPACKING AND INSTALLATION 2 - 2
7)
Connect the ADF with the copier using the relay harness.
<1> Connect the connector.
<2> Fit the harness to the copier using the supplied screw
(M3 × 8).
<3> Fit the grounding terminal to the copier using the supplied
screw (M3 × 6).
8)
Attach the rear cabinet.
Fit the four pawls located at the lower part of the rear cabinet
into the copier and secure the cabinet with the three screws.