INTRODUCTION SAFETY INSTRUCTIONS The information provided in this manual is intended to assist • Installation, maintenance and use should only be carried out by authorised personnel. in the installation and maintenance of the JET 6 Twin Coffee Brewer & FCG 6 grinder. Please read the instructions carefully •...
Page 4
PLUMBING LIMESCALE Permissible mains inlet water pressure: In common with all water boiler manufacturers, service calls Minimum 20kPa / 0.02MPa / 0.2bar / 2.9psi resulting from lime scale are not covered by warranty. Fitting Maximum 1000kPa / 1MPa / 10bar / 145psi a scale reducer is recommended, especially in hard water ar- The inlet water must be potable and free of contaminants.
TROUBLESHOOTING Fault Probable Cause Action Blank Screen The unit is not switched on Check the unit is plugged in correctly and switched on Plug or lead are damaged Call a qualified service technician Power supply Check power supply Internal wiring fault Call a qualified service technician Brewer not “Ready”...
Scroll though setup screens Set brewing temperature Set mode of operation (GRINDER / PACKS / MANUAL) Manual mode - This mode allows the user to set the desired amount of coffee needed. (See page X for setup). Grinder mode - This mode pairs brewer with the FCG6 grinder (See page X). Packs mode - This mode allows you to set custom pre-ground coffee pack sizes for use with the brewer (See page X for settings).