Power Failure; Alarm Connector (Rj45) - D-Link DGS-3710 Series Hardware Installation Manual

Table of Contents

Advertisement

DGS-3710 Series Layer 2 Managed Gigabit Switch Hardware Installation Guide
NOTE: Use a minimum 18 gauge (AWG) wire. All power connection wiring should conform to the
rules and regulations in the National Electrical Code (NEC), as well as any local codes. A branch
circuit over current protection must be rated below 20A.

Power Failure

The AC power and DC power of the device will backup each other immediately when one of the power sources fail. If
both power sources fail, unplug the Switch. When the power source has been restored, plug the Switch's power back
in.

Alarm Connector (RJ45)

The Alarm (RJ45) port pin assignment is layed out in the figure below.
Contact
Figure 2–6 Connecting a Switch to the DC Power source
Figure 2–7 Alarm (RJ45) Connector
Alarm Connector Port
1
2
3
4
5
6
7
8
Input (Channel 1)
Input (Channel 2)
Input (Channel 3)
Input (Channel 4)
18
Description
GND
GND
GND
GND

Advertisement

Table of Contents
loading

Table of Contents