- wash the steam wand with a wet cloth and remove any
milk residue;
- refi t the upper part in the steam wand (make sure it is
completely inserted);
Reassemble the external part of the Pannarello.
• (Fig.34) - Empty and clean the drip tray every day.
• Use a soft, dampened cloth to clean the appliance.
• (Fig.20) - Perform the following operations to clean the
pressurized fi lter holder:
- (Fig.9) - remove the fi lter and wash it thoroughly with hot
water.
- remove the adapter (if any) and wash it thoroughly with
hot water.
- wash the internal part of the pressurized fi lter holder.
• Do not dry the machine and/or its parts using a microwave
and/or standard oven.
• (Fig.35-36) - Clean the seat for accessories with a damp
cloth every week to remove any coff ee or dust residues.
Note: do not wash the pressurized fi lter holder
in the dishwasher.
11
DESCALING
Limescale builds up with the use of the appliance; the machine
needs descaling every 1-2 months and/or whenever a reduc-
tion in water fl ow is noticed. Use the Saeco descaling product
only.
In case of confl ict, priority must be given to
what is indicated in the operation and mainte-
nance manual over the instructions provided on sepa-
rately sold accessories and materials.
Use the Saeco descaling product (Fig. B). Its
formula has been designed to ensure better
machine performance and operation for its whole op-
erating life. If correctly used, it also avoids alterations
in the brewed product. Before starting a descaling cy-
cle make sure that: THE WATER FILTER (if used) HAS BEEN
REMOVED.
Never drink the descaling solution or any prod-
ucts dispensed until the cycle has been carried
out to the end. Never use vinegar as a descaling solu-
tion.
1 (Fig.13-14) - Insert the fi lter holder into the brew unit (8)
from the bottom and turn it from left to right until it locks
into place.
2 (Fig.1B) - Remove and empty the water tank.
• 12 •
3 (Fig.2) - Pour HALF the content of the Saeco concentrated
descaling solution into the water tank, then fi ll the tank
with fresh drinking water up to the MAX level.
4 Turn on the machine by pressing the ON/OFF button (11).
The indicator light (18) turns on.
(Fig.21) - Fill up (as described in chapter 7 of the manual)
2 cups of water (about 150 ml each) from the steam / hot
water wand and turn off the machine by pressing the ON/
OFF button (11); the light (18) turns off
5 Let the descaling solution take eff ect for approx. 15-20
minutes with the machine turned off .
6 Turn on the machine by pressing the ON/OFF button (11).
(Fig.21) - Fill up (as described in chapter 7 of the manual)
2 cups of water (about 150 ml each) from the steam / hot
water wand. Then turn the machine off by pressing the
ON/OFF button (11) and leave it off for 3 minutes.
7 Repeat the operations described in step 6 until the water
tank is completely empty.
8 (Fig.2) - Rinse the water tank with fresh drinking water
and fi ll it completely.
9 Place a container under the fi lter holder.
10 Switch on the machine by pressing the ON/OFF button (11);
turn the selection knob (17) to the "
means of the fi lter holder, dispense the whole content of
the tank. Set the selection knob (17) to the " " position to
stop dispensing.
11 (Fig.2) - Fill the tank again with fresh water.
(Fig.21) - Place a large enough container under the steam
wand (Pannarello). Open the water dispensing knob (3) by
turning it counter-clockwise.
(Fig.22) - Turn the selection knob (17) to the "
tion and dispense the whole content of the tank by means
of the steam / hot water wand.
12 (Fig.23) - After dispensing water, set the selection knob
(17) to the " " position to stop dispensing.
(Fig.24) - Close the water dispensing knob (3) by turning it
clockwise.
13 Repeat the operations from step (8) once again, for a total
of 4 tanks.
14 (Fig.19) - Remove the fi lter holder from the unit by turning
it from right to left and rinse it with fresh drinking water.
The descaling cycle is now complete.
(Fig.2) - Fill the tank again with fresh water. If necessary,
prime the circuit as described in section 4.5.
The descaling solution is to be disposed of ac-
cording to the manufacturer's instructions
and/or the regulations in force in the country of use.