7. PROBLEM CHART

PROBLEM
No power.

8. CLEANING AND MAINTENANCE

We recommend a frequent cleaning of the device. Please use a soft lint-free and moistened cloth. Never use
alcohol or solvents!
There are no servicable parts inside the device. Maintenance and service operations are only to be carried
out by authorized dealers.
Should you need any spare parts, please use genuine parts.
Should you have further questions, please contact your dealer.

9. TECHNICAL SPECIFICATIONS

Power supply:
Power consumption:
Number of control-channels:
Sound-control:
DMX 512-output:
Free chasers:
Dimensions (LxWxH):
Minimum mounting depth:
Weight:
Please note: Every information is subject to change without prior notice. 11/01 ©
CAUSE
The power unit is not connected.
DANGER TO LIFE!
Disconnect from mains before starting maintenance operation!
230 V AC, 50 Hz ~
via 9-12 V DC, 300 mA power unit included in the delivery
4 W
192
via built-in microphone
3-pin XLR-connector with polarity selector
6 x 240 scenes
483 x 132 x 80 mm
19" mounting dimensions with 3 u
170 mm
2.5 kg
Check the connection cable of the
power unit and any extension-cables.
20