Installing Cabinetry OverYourJenn-Air Grill
Electrical W iringInformation
A* = 30" (76.2 cm) minimumclearance betweenthe top of
The neutralof thisunitis groundedto theframe throughthe
thecookingplatformandthebottomofanunprotected
green groundingwire. If local conditionsdo not permit
wood or metal cabinet,
grounding of theneutral, untwist or disconnect the green
wire and connect the green wire to ground in accordance
A* = 24" (60.96 cm) minimum clearance when bottom of
with local codes. Connect the white neutral to the service
wood or metal cabinet is protected by not less than
neutral.
1/4" (0.635 cm) FLAME RETARDANT millboard
covered with no less than no. 28 MSG sheet steel,
0.015" (0.038 cm) stainless steel, 0.024" (0.061 cm)
ProperElectric Supply
aluminumor copper.
You mustprovidean adequateelectrical supplysystem as
required for your cooktop. All wire connections must be in
Dottedlines
accordance with local codes and properlyinsulated. Check
indicate
with local utility for governing electrical codes and
rangehood
ordinances.In the absence of local electrical codes, the
construction
NationalElectricalCode, NFPA No. 70, governingelectric
range installations must be followed. A copy of the National
\/_
....
ElectricalCode, NFPA No. 70, can be obtainedby wdtingto:
j_E -_
NATIONAL FIRE PROTECTION ASSOC.
Battery,march Park
Quincy, Massachusetts 02269
L_
-__--
A three-wire, single phase, A.C. 120/240 volt 60 cycle
electrical system (properly circuit protected to meet Local
* To eliminate the risk of burns or fire by reaching over
Codes of NFPA No. 70) must be provided. Unit must be
heated surface units, cabinet storage space located
properly grounded in accordance with local wiring code. The
above the surface units should be avoided. If cabinet
chart below recommends the minimum circuit protector and
storage is to be provided, the risk can be reduced by
wire sd_eif the appliance is the only unit on the circuit. If
installing a range hood that projects horizontally a
smaller sizes of wire are used, the unit efficiency will be
minimum of 5 inches beyond the bottom of the cabinets,
reduced and a fire hazard may be created. It is advisable
that the electrical wiringand hookup be accomplished by a
InstallerInstallation Suggestions
competent electrician.
1. Chamfer all exposed edges of decorative laminate to
RECOMMENDED
MINIMUM
prevent damage from chipping.
2. Radius comers of cutout and file to insure smooth
K.W. RATING CIRCUIT PROTECTION WIRE SIZE, REMOVE
edges and prevent corner cracking. Recommend
ONSERIAL PLATE
INAMPERES
AWG
KNOCKOUT
114"or 3/8" diameter drill in each comer,
0 -
4,9
20
12
NO
5.0 -
6.9
30
10
NO
3. Rough edges, inside corners which have not been
7.0 -
9.9
40
8
NO
roundedand forced fitscan contributeto crackingof the
10.0 - 11.9
50
8
**YES
countertop laminate.
12.0 - 14.9
60
6
**YES
4. Countertopmustbe supportedwithin3" of cutout.