Figure 13A
If a wall mount installation is required, the installation
bracket should meet the requirement in the installation
bracket diagram and the wall should be able to support
the installation.
Be sure there are no obstacles blocking air discharge.
The installation wall should be constructed of brick, con-
crete or another surface of equal strength to hold the
unit safely. Make sure the connections to the wall,
bracket and unit are firmly seated and there are no ob-
structions to the airflow.
Anchoring the outdoor unit
The unit should be tightly anchored, horizontally, with a nut
and bolt ( 10 or
8) on a concrete or similarly rigid, stable
surface.
Unit Dimensions
Model
Inches/mm (L1xHxW1)
31" x 21" x 10"
MS*12*E15
780 x 540 x 250
30" x 23" x 11"
MS*18*E15
760 x 590 x 285
30" x 23" x 11"
MS*12*E19
760 x 590 x 285
33" x 27.5" x 12.5"
MS*18*E19
840 x 700 x 320
Figure13B
L2
Figure 14
Outdoor
Mounting Dimensions
L2 (mm)
21.5"
549
21"
530
21"
530
22"
560
Drain joint installation
NOTE: Drain joints differ slightly according to the different
outdoor units. Inspect your unit and use the installation in-
structions for your specific unit.
For drain joints with seals (Figure 15A):
Slide the seal onto the drain joint and insert into the
base pan hole of the outdoor unit. Rotate 90° to secure
(see Figure 16).
For drain joints without seals (Figure 15B):
Insert the drain joint into the base pan hole of the out-
door unit until it remains fixed, accompanied by a click-
ing sound.
NOTE: For protection against water condensation off the out-
door unit during heating mode, connect the drain joint with an
extension drain hose (provided by the installer).
(Figure 15A)
L1 (mm)
11"
276
11.5"
290
11.5"
290
13"
335
6
(Figure 15B)
Correct alignment
Incorrect alignment
Figure 16