Download Print this page

Midea M2OC-14HRDN1 Technical & Service Manual page 26

Multi split type, heat pump air conditioners r410a multi dc inverter
Hide thumbs Also See for M2OC-14HRDN1:

Advertisement

For M5OA-36HRDN1-Q model
Display
E0
E2
E3
E4
E5
E6
F1
F2
F3
F4
F5
P0
P1
P2
P3
P4
P5
P6
EEPROM error
Communication malfunction between outdoor unit and indoor units
Communication malfunction between outdoor main chip and compressor control chip.
Outdoor unit temp. sensor or connector of temp. sensor is defective
Compressor voltage protection
PFC module protection
No A Indoor unit coil outlet temp. sensor or connector of sensor is defective
No B Indoor unit coil outlet temp. sensor or connector of sensor is defective
No C Indoor unit coil outlet temp. sensor or connector of sensor is defective
No D Indoor unit coil outlet temp. sensor or connector of sensor is defective
No E Indoor unit coil outlet temp. sensor or connector of sensor is defective
Compressor top. temperature protection
High pressure protection
Low pressure protection
Compressor current protection
Compressor discharge high-temperature protection
Condenser high-temperature protection
Inverter module protection
LED STATUS