Trouble shooting
Product doesn't work but has power.
Power
supply is
normal?
Yes
power cord
connection
is normal?
Yes
chamber
noodle disc,
front panel
assemble
well ?
Yes
Safety
Switch
works ?
Yes
Button and
light works?
Yes
Motor
works
No
The range of working voltage
is ??.
No
connection fault
No
Installation fault
No
Safety Switch fault
No
Control PCBA failed
No
Motor fault
Check the power supply.
Re-connect power cord
Re-install
Replace Safety Switch
Replace Control PCBA
Replace Motor