Technical Data; Troubleshooting - EINHELL HGG 120 NIRO Operating Manual

Hot-air generator
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 8

Technical Data

Nominal heat load Qu:
Air throughput:
Connection:
Type of gas:
Operating pressure P:
Mains power supply:
Trouble Shooting
Problem
Motor doesn't start
Piezo doesn't ignite
No gas at burner
Burner ignites, flame is
extinguished as soon as the gas
valve is released
-
Burner goes out while in use
Important!
Have repairs carried out only by specialist workshops or ISC.
HGG 120 NIRO
HGG 120 NIRO CH
Max. (Hs) 12 kW
500 m
3
/h
G 30: 1,17 kg/h P/B
commercially available
propane (DIN 51622)
Commercially available
butane (DIN 51622)
300 m bar
230 V ~ 50 Hz 38 W
Tested in accordance with DIN-DVGW
Made in Germany
Cause
No electricity
Electrode incorrectly adjusted
- Gas valve is closed
- Gas cylinder is empty
- Gas hose or connection leaks
- The thermoelement was not
-
warm enough
- The safety thermostat
-
switches off
- Gas flow too high
- Air input too low
HGG 200 NIRO
max. (Hs) 20 kW
500 m
3
/h
G 31:1,43 kg/h
commercially available
propane (DIN 51622)
1,5 bar
230 V ~ 50 Hz 38 W
Remedy
- Check electrical outlet
- Check mains cable
Check electrode and precisely
set according to diagram
- Open valve
- New gas cylinder
- Locate point of leak with soap
-
- Repeat ignition procedure
-
-
- Allow the heater to cool for a
-
- Have the pressure regulator
-
-
- Check the suction grid and
-
- Inspect ventilator
HGG 300 NIRO
max. (Hs) 30 kW
500 m
3
/h
G 31: 2,15 kg/h
commercially available
propane (DIN 51622)
1,5 bar
230 V ~ 50 Hz 38 W
foam and repair
while pressing in the gas
valve knob
few minutes and reignite
inspected and replace if
necessary
clean
GB
11