Control Panel; Main Electronic P.c.b. Box - Biasi Inovia ERP Series Service Manual

G.c. appl. no. 47-583-38, 47-583-39, 47-583-40, 41-583-30
Table of Contents

Advertisement

GENERAL ACCESS AND EMPTYING HYDRAULIC CIRCUITS

2 .3 control panel

warning: isolate the boiler from the mains electrici-
ty supply before removing any covering or compo-
nent .
To gain access to the parts located inside the control panel pro-
ceed as follows:
1 Remove the front panel of the case
2 Unscrew the screws D and E (Figure 2.5).
3 Free the hooks indicated and rotate the lid towards left.
e
figure 2 .5
4 To access to the parts located behind the control panel turn it
as shown in Figure 2.6.
figure 2 .6
2 .4 main electronic p .c .b . box
warning: isolate the boiler from the mains electrici-
ty supply before removing any covering or compo-
nent .
To gain access to the parts located into main electronic p.c.b. box
proceed as follows:
1 Remove the front panel of the case.
- 6 -
d
terminal block lid removal
2 To remove the terminal block lid F (Figure 2.7), free the front
hooks.
f
figure 2 .7
3 Slightly rotate the lid as indicated by the curved arrow and
free the rear hooks.
4 Remove the lid.
main electronic p .c .b . lid removal
To get access to the main electronic p.c.b.:
5 Pull the box that contains the electronic p.c.b. and rotate it
(Figure 2.8).
figure 2 .8
6 Remove the terminal block lid F (Figure 2.7).
7 Free the hooks placed on the three sides indicated and rotate
the lid towards left (Figure 2.9).

Advertisement

Table of Contents
loading