Cleaning centrifugal oil filter
and replacing filter sleeve
1.
Remove nut, holding the rotor with an oil
filter wrench.
2.
Remove nut (1), washer (2), rotor cap (3)
and O-ring (4).
3.
Remove filter sleeve (1).
4.
Measure the layer thickness of the oil resi-
due.
5.
If maximum layer thickness (25 mm) is ex-
ceeded, shorten maintenance interval.
6.
Clean rotor components and remove strain-
ers (2).
7.
Wash standpipes (3) and nozzles (4) with
cleaner, blow out with compressed air.
8.
Insert the new filter sleeve with the smooth
surface facing the rotor cap.