2=12,INDOOR UNIT INSTALLATION
,
Hook the top of the indoor unit on the indoor unit mounting
bracket (7).
Use the included wood screws (9) and washer (10), and fasten the indoor unit at 2
Iocations(,._) each at the top and the middle of the unit.
2-13.FRONT
PANEL INSTALLATION
1 ) Open the horizontal vane for the upper air outlet.
2) Fit the front panel onto the indoor
unit from the front, and then push the upper
and lower areas that are marked with arrows.
3) Push the areas below the upper air outlet and the areas above and below the
lower air outlet that are marked with arrows.
4) After installing the front panel, install the 2 screws below the upper air outlet.
co
26-17/32(674)
4
t
co
co
co
i
co
o
o4
co
03
i
co
3-1. PURGING PROCEDURES AND LEAK TEST
Refer to the procedures
indicated in the installation manual of the outdoor unit.
3-2, TEST RUN
Make sure the following
is done.
, The area around the damper is free of any objects, and the movement of the damper is not blocked.
, Panel is installed correctly.
, Indoor and outdoor units are installed correctly, and power is supplied.
1) Press the E.O. SW once for COOL, and twice for HEAT operation.
Test run will be performed
for 30 minutes.
If
the left lamp of the operation indicator blinks every 0.5 seconds, inspect the indoor/outdoor
unit connecting
wire (A)
for mis*wiring. After the test run, emergency
mode (set temperature
75°F (24°C)) will start.
2) To stop operation,
press the E.O. SW several times until all LED lamps turn off. Refer to operating instructions
for
details.
Checking the remote
(infrared)
signal
reception
Press the ON/OFF button on the remote controller
and listen for an audible indicator from the indoor unit. Press the
ON/OFF
button again to turn the air conditioner
oft.
Emergency
_4-_) I°P erati....
itch
_
(E.O. SW)
Once the compressor
stops, the restart preventive
device operates so the compressor
will not operate for 3 minutes to protect the air conditioner.
3-3. AUTO RESTART FUNCTION
This product is equipped
with an auto restart function.
When the power supply is cut off during operation,
such as during blackouts,
the function automatically
starts
operation in the previous setting once the power supply is resumed. (Refer to the operating
instructions
for details.)
Caution:
0 After test run or remote signal reception check, turn off the unit with the E.O. SW or the remote controller
before turning off the power supply. If this procedure is
not performed,
the unit will automatically
begin operation when power supply is resumed.
To the user
,
After installing the unit, explain to the user about auto restart function.
I °
If auto restart function is unnecessary,
it can be deactivated.
Consult the service representative
to deactivate
the function.
Refer to the service manual for de*
L
tails.
3-4. EXPLANATION
TO THE USER
Using the OPERATING
INSTRUCTIONS,
explain to the user how to use the air conditioner
(the remote controller,
removing the air filters, placing or removing the
remote controller from the remote controller holder, cleaning methods, precautions for operation, etc.)
,
Recommend
that the user read the OPERATING
INSTRUCTIONS
carefully.
Refer to the procedures
indicated in the installation manual of the outdoor unit.
the refrigerant
pipes. The compressor
may burst if air etc. get into it.