dCV measuring
Connect the black measuring wire to the
„COM" connector, and the red one to the „V/Ω"
connector.
Set the function switch to the proper DCV
setting, and connect the wires to the circuit.
note:
if you are unsure about the measured voltage range, set
the function switch to a high range.
if the lCd shows „1" it means overload, and the range
should be set to a higher value.
aCV measuring
Connect the black measuring wire to the
„COM" connector, and the red one to the „V/Ω"
connector.
Set the function switch to the proper ACV
setting and connect the wires to the circuit.
note:
if you are unsure about the measured voltage range, set
the function switch to a high range.
if the lCd shows „1" it means overload, and the range
should be set to a higher value.
dCa measuring
Connect the black measuring wire to the
„COM" connector, and the red one to the „mA"
connector (max. 200mA), or connect the red
wire to the „20A" connector (max. 20A).
Set the function switch to the proper DCA
setting and connect the wires to the circuit.
note:
if you are unsure about the measured voltage range, set
the function switch to a high range.
if the lCd shows „1" it means overload, and the range
should be set to a higher value.
max inward current 200ma or 20a (depending on the
placement of the red wire), in case of an exceeding
current the fuse will melt.
aCa measuring
Connect the black measuring wire to the
„COM" connector, and the red one to the „V/Ω"
connector.
Set the function switch to the proper ACA
setting, and connect the wires to the circuit.
note:
if you are unsure about the measured voltage range, set
the function switch to a high range.
if the lCd shows „1" it means overload, and the range
should be set to a higher value.
max inward current 1000V.
resistance measuring
Connect the black measuring wire to the
„COM" connector and the red one to the V/Ω
connector.
Set the function switch to the proper
resistance setting and connect the wires to the
measured resistor.
note:
if the measured resistance value is over the chosen max
value the lCd will show „1" and the function switch
needs to be set to a higher range. it may take a few
seconds for the device to stabilize when measuring
above 1mΩ
Capacity measuring
Connect the wire to the „V/Ω „ connector and
the red one to the „COM" connector.
Set the function switch to a proper capacity
setting and connect the wires to the measured
capacitor.
note:
if you are unsure about the measured capacity set the
function switch to a high range.
if the lCd shows „1" it means overload and the function
switch needs to be set to a higher range.
to be safe, discharge the measured capacitor before
measuring.
diode and continuity test
Connect the black measuring wire to the
„COM" connector, and the red one to the „V/Ω"
connector (Note: the red wire's polarity is „+")
Set the function switch to the „
connect the wires to the measured diode.
Connect the wires to the diode's measuring
points, if the device beeps, the resistance is
lower than appr. (70±20)Ω
temperature measuring
Connect the red wire to the mA, and the black
one to the "COM" connector. Touch the end
of the thermometer to the measured object
and the temperature value is displayed on the
screen in degrees Celsius.
hFe
Set the function switch to hFE.
Place the part into the transistor connector
depending on whether it is NPN or PNP type.
automatic turn-off
If the device is not used for 15 minutes it turns
off automatically. To use it again, turn the
function switch.