Air-Conditioners For Building Application

INDOOR UNIT

PCFY - P VKM-E

INSTALLATION MANUAL

For safe and correct use, read this manual and the outdoor unit installation manual thoroughly before installing
the air-conditioner unit.
INSTALLATIONSHANDBUCH
Aus Sicherheitsgründen und zur richtigen Anwendung vor Installation der Klimaanlage die vorliegende Bedie-
nungsanleitung und das Installationshandbuch gründlich durchlesen.
MANUEL D'INSTALLATION
Avant d'installer le climatiseur, lire attentivement ce manuel, ainsi que le manuel d'installation de l'appareil exté-
rieur pour une utilisation sûre et correct.
INSTALLATIEHANDLEIDING
Lees deze handleiding en de installatiehandleiding van het buitenapparaat zorgvuldig door voordat u met het
installeren van de airconditioner begint.
MANUAL DE INSTALACIÓN
Para un uso seguro y correcto, lea detalladamente este manual de instalación antes de montar la unidad de
aire acondicionado.
MANUALE DI INSTALLAZIONE
Per un uso sicuro e corretto, prima di installare il condizionatore d'aria leggere attentamente il presente manuale
ed il manuale d'installazione dell'unità esterna.
MANUAL DE INSTALAÇÃO
Para uma utilização segura e correcta, leia atentamente este manual e o manual de instalação da unidade exte-
rior antes de instalar o aparelho de ar condicionado.
For use with the R410A
Bei Verwendung von R410A
A utiliser avec le R410A
Bij gebruik van R410A
Para utilizar con el R410A
FOR INSTALLER
FÜR INSTALLATEURE
POUR L'INSTALLATEUR
VOOR DE INSTALLATEUR
PARA EL INSTALADOR
PER L'INSTALLATORE
PARA O INSTALADOR
Uso del refrigerante R410A
Para utilizaçao com o R410A
R410A ile beraber kullanmak için
English (GB)
Deutsch (D)
Français (F)
Nederlands (NL)
Español (E)
Italiano (I)
Português (P)
Türkçe (TR)

Advertisement

loading

Summary of Contents for Mitsubishi Electric PCFY-P VKM-E

  • Page 1: Indoor Unit

    Air-Conditioners For Building Application INDOOR UNIT PCFY - P VKM-E For use with the R410A Uso del refrigerante R410A Bei Verwendung von R410A A utiliser avec le R410A Para utilizaçao com o R410A Bij gebruik van R410A R410A ile beraber kullanmak için Para utilizar con el R410A INSTALLATION MANUAL FOR INSTALLER...
  • Page 2 Contents 1. Safety precautions ..................2 ..................5 2. Installation location ..................2 ....................5 3. Installing the indoor unit................2 ..................7 4. Installing the refrigerant piping ..............4 Note: : Indicates an action that must be avoided. : Indicates that important instructions must be followed. : Indicates a part which must be grounded.
  • Page 3 Models 1237 1280 P100,125 1557 1600 Models 86 2 P100,125 A Front side outlet F Left drain tubing B Left side outlet G Gas tubing C Right side outlet H Liquid tubing I Rubber plug E Right drain tubing sion bolts and tubing and prepare relative holes. A Pattern paper B Suspension bolt hole C Indoor unit width...
  • Page 4 Installing procedures 7~12 D Suspending bolt E Washer 1 F Double nuts 882 - 887 1202 - 1207 P100, P125 1522 - 1527 45°±2° ing flare nut. Insulate carefully. Warning: A Flare cutting dimensions Copper pipe O.D. Flare dimensions ø6.35 8.7 - 9.1 ø9.52 12.8 - 13.2...
  • Page 5 downward slope. port of the drain tubing. A Drain pan B Plug C Insert the driver etc.in the plug deeply. 5 supplied with the unit to the drain port on the unit with a vinyl chloride adhesive. 5 with a vinyl chloride adhesive.
  • Page 6 A Switch 16 A D Total operating current be less than 16 A B Overcurrent protection 16 A E Pull box C Indoor unit Types of transmission cable M1 M2 S Cable diameter More than 1.25 mm² TB15 Length Less than 200m Types of remote control cable Cable diameter 0.5 to 1.25 mm²...
  • Page 7 If you want to sense room temperature with the built-in sensor in a remote lation location. the heating thermometer is OFF. warm may occur. P40, P63 3.5 m 2.7 m 2.5 m P100, P125 4.2 m 3.0 m 2.6 m Warning: B Test run display 1 Turn on the power at least 12 hours before the test run.
  • Page 8 1280 1600 1600...
  • Page 9 1237 1280 1557 1600 86 2 ø65 ø100 (mm)
  • Page 10 7~12 45°±2° R410A...
  • Page 12 M1 M2 S TB15 M1 M2 M1 M2 M1 M2 TB15 TB5 TB15 M1 M2 M1 M2 M1 M2 CN90 CN90 Pair No. Pair No. M1 M2 M1 M2 M1 M2 TB15 TB15 Pair No. CN43 1 2 3 4 5 6 7 8 9 10 CN82 SW14 SW12...
  • Page 13 TEST RUN COOL, HEAT °C °C SIMPLE TEMP. ON/OFF MENU ON/OFF FILTER BACK MONITOR/SET CHECK TEST PAR-21MAA CLOCK OPERATION CLEAR...
  • Page 14 This product is designed and intended for use in the residential, commercial and light-industrial environment. Importer: Mitsubishi Electric Europe B.V. Capronilaan 46, 1119 NS, Schiphol Rijk, The Netherlands French Branch 25, Boulevard des Bouvets, 92741 Nanterre Cedex, France German Branch...