Mitsubishi SRK63ZM-S Technical Manual page 82

Inverter wall mounted type residential air-conditioners (split system, air to air heat pump type)
Table of Contents

Advertisement

Sheath
The range of temperature setting
Upper
When shipped, the range of set temperature differs depending on the operation mode as below.
Upper case
Board
Lower
Wiring
In case of pulling out from
upper center
2
.
of sheath
Upper
Board
Lower
Heating : 16 ~ 30°C (55 ~ 86°F)
Except heating (cooling, fan, dry, automatic) : 18 ~ 30°C (62 ~ 86°F)
Upper limit and lower limit of set temperature can be changed with remote control.
Upper limit setting: valid during heating operation. Possible to set in the range of 20 to 30°C (68 to 86°F).
Lower limit setting: valid except heating (automatic, cooling, fan, dry) Possible to set in the range of 18 to 26°C (62 to
79°F).
When you set upper and lower limit by this function, control as below.
1. When
TEMP RANGE SET, remote control function of function setting mode is "INDN CHANGE" (factory setting),
If upper limit value is set
During heating, you cannot set the value exceeding the upper limit.
If lower limit value is set
During operation mode except heating, you cannot set the value below the lower limit.
2. When
TEMP RANGE SET, remote control function of function setting mode is "NO INDN CHANGE"
If upper limit value is set
During heating, even if the value exceeding the upper limit is set, upper limit value will be sent to the indoor unit.
But, the indication is the same as the temperature set.
If lower limit value is set
During except heating, even if the value lower than the lower limit is set, lower limit value will be sent to the indoor unit.
But, the indication is the same as the temperature set.
How to set upper and lower limit value
1. Stop the air-conditioner, and press
seconds .
The indication changes to "FUNCTION SET
2. Press
button once, and change to the "TEMP RANGE
3. Press
(SET) button, and enter the temperature range setting mode.
4. Select "UPPER LIMIT
" or "LOWER LIMIT
5. Press
(SET) button to fix.
6. When "UPPER LIMIT
" is selected (valid during heating)
Indication: "
SET UP"
Select the upper limit value with temperature setting button
(blinking)
Press
(SET) button to fix. Indication example: "UPPER 26°C" (Displayed for two seconds)
After the fixed upper limit value displayed for two seconds, the indication will return to "UPPER LIMIT
7. When "LOWER LIMIT
" is selected (valid during cooling, dry, fan, automatic)
Indication: "
SET UP"
Select the lower limit value with temperature setting button
(blinking)
Press
(SET) button to fix. Indication for example: "LOWER 24°C" (Displayed for two seconds)
After the fixed lower limit value displayed for two seconds, the indication will return to "LOWER LIMIT
8. Press ON/OFF button to finish.
It is possible to finish by pressing
ON/OFF button on the way, but
unfinished change of setting is
unavailable.
During setting, if you press
(RESET) button, you return to the
previous screen.
(SET) and
(MODE) button at the same time for over three
".
" indication.
" by using
button.
"UPPER 30°C
"
. Indication example: "UPPER 26°C
"LOWER 18°C
"
. Indication example: "LOWER 24°C
81
-
-
'13 • SRK-T-142
PJA01 2D7 30
"
".
"
".
Previous button

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Srk71zm-sSrk80zm-s

Table of Contents