Mitsubishi SRK63ZM-S Technical Manual page 58

Inverter wall mounted type residential air-conditioners (split system, air to air heat pump type)
Table of Contents

Advertisement

3)
Reset conditions:
a)
b)
(ii)
Heating
1)
Operating conditions:
2)
Detail of operation:
3)
Reset conditions:
a)
b)
(r)
Refrigeration cycle system protection
(i)
Starting conditions
1)
When 5 minutes have elapsed after the compressor ON or the completion of the defrost control
2)
Other than the defrost control
3)
When, after meeting the conditions of 1) and 2) above, the compressor speed, indoor air temperature (Th1) and indoor
heat exchanger temperature (Th2) have met the conditions in the following table for 5 minutes:
Operation mode
Cooling
Heating
Note (1) Except that the fan speed is HI in heating operation and silent mode control.
(ii) Contents of control
1)
When the conditions of (i) above are met, the compressor stops.
2)
Error stop occurs when the compressor has stopped 3 times within 60 minutes.
(iii) Resetting condition
When the compressor has been turned OFF
(s) Service valve (gas side) closing operation
(i)
Starting conditions
1)
Operation mode : Heating
2)
Compressor conditions : OFF
(ii) Contents control
If the output current of inverter exceeds the specifications, it makes the compressor stopping.
(iii) Anomalous stop control
1)
If the inverter output current value exceeds the setting value within 80 seconds the compressor stops.
2)
After 3-minute delay, the compressor restarts, but if this anomaly occurs 2 times within 20 minute after the initial
detection.
24
5
Compressor speed (N)
Indoor air temperature (Th1)
40 N
< =
40 N
< =
(1)
ON
3
1
Indoor air temperature (Th1)/
Indoor heat exchanger temperature (Th2)
10 Th1 40
< =
< =
< =
< =
0 Th1 40
57
-
-
'13 • SRK-T-142
7
Th1−4<Th2
Th2<Th1+6