Mitsubishi SRK63ZM-S Technical Manual page 76

Inverter wall mounted type residential air-conditioners (split system, air to air heat pump type)
Table of Contents

Advertisement

blocks ② and ③ oscillating between
DC 0 and 20V?
YES
Indoor electrical components
are normal.
(b) Indoor unit fan motor check procedure
1) Indoor PCB output check
DC several V
(4~6 V)
CNU
2) Fan motor resistance check
Measuring point
① − ③
④ − ③
Replace indoor PCB.
(–)
GND
DC15V
FM
I
Resistance when normal
M
k
75
-
① ④
DC 308~336V
Indoor PCB
-
'13 • SRK-T-142
Measuring
Voltage range when
point
normal
① − ③
④ − ③
⑤ − ③

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Srk71zm-sSrk80zm-s

Table of Contents