USER'S MANUAL
CAESAR SERIES
ASH-18AC PT, ASH-24AC PT

Advertisement

Table of Contents
loading

Summary of Contents for Sinclair ASH-18AC PT

  • Page 1 USER'S MANUAL CAESAR SERIES ASH-18AC PT, ASH-24AC PT...
  • Page 2  ...
  • Page 3: Table Of Contents

    CONTENTS Operation and maintenance .............1 ■ Notices for operation ..............3 ■ Notices for use ...........5 ■ Names and functions of each part ..........7 ■ Operation of remote controller ■ ............13 Emergency operation ■ ..............14 Clean and care ..............16 ■ Troubleshooting Installation service ■...
  • Page 4: Operation And Maintenance Notices For Operation

    Operation and maintenance-notices for operation ★ ★ Be sure to pull out the power ★ Earth: The ground Select the most appropriate tem- perature. be connected! plug when not using the air co- nditioner for a long time. Keep room cooler than outside about 5 degree.
  • Page 5 Notices for operation ★ The airflow direction can be adjusted appro- ★ If the supply cord is damaged, it must be replaced priately. At operating, adjust the vertical airflow by the manufacturer or its service agent or a direction by adjusting the louvers of upward/do- similarly qualified person in order to avoid a wnward direction.
  • Page 6: Notices For Use

    Notices for use Working principle and special functions for cooling Principle: Air conditioner absorbs heat in the room and transmit to outdoor and discharged, so that indoor ambient temperature decreased, its cooling capacity will increase or decrease by outdoor ambient temperature. Anti-freezing function: If the unit is running in COOL mode and in low temperature, there will be frost formed on the heat exchanger, when indoor heat exchanger temperature decreased below 0...
  • Page 7 Notices for use Working temperature range Indoor sideDB/WB( Outdoor sideDB/WB( Maximum cooling 32/23 43/26 Maximum heating 27/--- 24/18 The operating temperature range (outdoor temperature) for cooling only unit is 18℃~ 43℃; for heat pump unit is -7℃~ 43℃. Working temperature range Indoor sideDB/WB( Outdoor sideDB/WB( Minimum cooling...
  • Page 8: Names And Functions Of Each Part

    Names and functions of each part Indoor unit Air in ⑴ ⑶ ⑷ Air out ⑸ The pattern in displayer: :Cool :Dry ⑵ Power cable ⑴ :Fan :Heat ⑵ Remote control : Wireless Front panel ⑶ remote control :Set temp. ⑷...
  • Page 9: Operation Of Remote Controller

    Operation of remote controller ON/OFF Press it to start or stop operation. : Press it to decrease temperature setting. : Press it to increase temperature setting. Press it to set fan speed. MODE Press it to select operation mode (AUTO/COOL/DRY/FAN/HEAT). I FEEL(Page 10) Press it to set HEALTH function Press it to set AIR function.
  • Page 10: Digital Display

    Operation of remote controller 19 20 21 22 MODE icon: LIGHT icon: If MODE button is pressed, is displayed by pressing the current operation mode icon LIGHT button. Press LIGHT button again to clear the display. (AUTO), ( COOL), (DRY), (FAN) or (HEAT LOCK icon:...
  • Page 11 Operation of remote controller 19 20 21 22 AIR icon: HEALTH icon: is displayed when pressing the is displayed when pressing the AIR button.Press this button again HEALTH button. Press this button to clear the display. again to clear the display. I FEEL icon: X-FAN icon: is displayed when pressing the...
  • Page 12 Operation of remote controller Remote Controller Description ON/OFF : Press this button to turn on the unit .Press this button again to turn off the unit. Press this button to decrease set temperature. Hold it down for above 2 seconds to rapidly decrease set temperature.
  • Page 13 Operation of remote controller TIMER ON : Press this button to initiate the auto-ON timer. To cancel the auto-timer program, simply press this button again. After pressing this button, disappears and "ON "blinks . 00:00 is displayed for ON time setting.
  • Page 14 Operation of remote controller SLEEP: Press this button to go into the SLEEP operation mode. Press it again to cancel this function. This function is available in COOL, HEAT (Only for models with heating function) or DRY mode to maintain the most comfortable temperature for you. LIGHT: Press LIGHT button to turn on the display's light and press this button again to turn off the display's light.
  • Page 15: Emergency Operation

    Emergency operation Displayer indicator light control of indoor unit It's a special selective button for the users ,who are not accustomed to the light at sleeping. Get the displayer indicator light on: When setting the light function,the mark will ● display on the remote controller screen by pressing this button.
  • Page 16: Clean And Care

    Clean and care Caution Turn power off and pull out the power plug before cleaning air conditioner, or it may cause electric ● ● shock. Never sprinkle water on the indoor unit and the outdoor unit for cleaning because it can cause an ●...
  • Page 17 Clean and care Check before use ① Be sure that nothing obstructs the air outlet and intake vents. ② Check that whether ground wire is properly connected or not. ③ Check that whether the batteries of air conditioner are changed or not. ④...
  • Page 18: Troubleshooting

    Troubleshooting CAUTION Don't attempt to repair the air conditioner by yourself, it can cause an electric shock or fire. Please check the following items before asking for repair, it can save your time and money. Phenomenon Troubleshooting Not operate immediately when the air Once the air conditioner is stopped, it will ●...
  • Page 19 Troubleshooting Phenomenon Troubleshooting Has the power been shut down? ● The unit can not run. Is power plug loosed? ● Is the circuit protection device tripped off or not? ● Is voltage higher or lower? ● (Tested by professionals) Breaking off Is the TIMER correctly used? ●...
  • Page 20 Troubleshooting Phenomenon Troubleshooting Indoor unit cannot deliver air. In HEAT mode, when the temperature of indoor ● heat exchanger is very low, that will stop deliver air in order to prevent cool air. (Within 2min) In HEAT mode, when the outdoor temperature ●...
  • Page 21: Notices For Installation

    Notices for installation Important Notices 1. The unit installation work must be done by qualified personnel according to the local rules and this manual. 2. Before installation, please contact with local authorized maintenance center, if unit is not installed by the authorized maintenance center, the malfunction may not solved, due to discommodious contacts.
  • Page 22 Notices for installation Safety Requirements For Electric Appliances 1. The power supply should be used the rated voltage and AC exclusive circuit, the power cable diameter should be satisfied. 2. Don't drag the power cable emphatically. It should be reliably earthed, and it should be connected to the special earth device, the installation work should be operated by the professional.
  • Page 23: Installation Dimension Diagram

    Installation dimension diagram Installation dimension diagram Space to the ceiling 15cm Above Space to the wall 15cm Above 15cm Above Space to the wall 300cm Above Above Air outlet side Space to the floor The dimensions of the space necessary for correct ●...
  • Page 24: Install Indoor Unit

    Install indoor unit Install the rear panel 1.Always mount the rear panel horizontally. Due to the water tray of indoor unit has been adopted the both-way drainage design, the outlet of water tray should be adjusted slightly down when installing, that is taking the outlet of the water tray as the center of a circle, the included angle between the evaporator and level should be 0 or more, that is good for condensing water drainage.
  • Page 25: Install Indoor Unit

    Install indoor unit NOTE: When connecting the electric wire if the wire length is not enough, please contact with the authorized service shop to buy a exclusive electric wire that is long enough and the joint on the wire are not allowed. The electric wiring must be correctly connected, wrong connection may cause spare parts ●...
  • Page 26: Install Outdoor Unit

    Install outdoor unit Electric wiring Disassemble the handle on the outdoor unit right side plate. Take off cord anchorage. Connect and fix power connect cord (for cooling and heating unit,connect and fix power connect cord and signal control wire) to terminal block. Fix the power connection cable with cord anchorage, (for cooling and heating unit, use the cord anchorage 12、18K Heat pump type:...
  • Page 27: Install Outdoor Unit

    Install outdoor unit Condensate drainage of outdoor unit (no for cooling only) The condensate and defrosting water formd during heating in the outdoor unit can be properly discharged by drainage pipe . Ø Installation method:set the drain connection in 25 hole of the chassis has been installed and then connect drainage pipe Chassis with drain nozzle,so that condensate and defrosting waer can...
  • Page 28: Check After Installation And Test Operation

    Check after installation and test operation Check after installation Items to be checked Possible malfunction Has it been fixed firmly? The unit may drop, shake or emit noise. It may cause insufficient cooling(heating) Have you done the refrigerant leakage test? capacity It may cause condensation and dripping.
  • Page 29: Installation And Maintenance Of Healthy Filter

    Installation and Maintenance of Healthy Filter Installation Instructions 1. Forcibly pull the panel for a specific angle from the two ends of the front panel according to the arrow direction. Then pull the air filter downwards to remove it. (See Fig.a) Fig.
  • Page 30: Configuration Of Connection Pipe And Additional Volume Of Refrigerant

    Configuration of connection pipe and additional volume of refrigerant 1. Standard length of connection pipe 5m、7.5m、8m 2. Min length of connection pipe For the unit with standard connection pipe of 5m, there is no limitation for the min length of connection pipe. For the unit with standard connection pipe of 7.5m and 8m, the min length of connection pipe is 3m.
  • Page 31 Configuration of connection pipe and additional volume of refrigerant Sheet 2. Additional refrigerant charging amount for R22 R407C R410A and R134a Diameter of connection pipe mm Indoor unit throttle Outdoor unit throttle Liquid pipe Gas pipe Cooling only, Cooling only Cooling and cooling and heating (g / m)
  • Page 32 SERIES CAESAR MODEL ASH‐09AC PT ASH‐13AC PT ASH‐18AC PT ASH‐24AC PT ASH‐28AC cooling Capacity heating Power supply 220‐240 220‐240 220‐240 220‐240 220‐240 cooling 16,1 Power current heating 15,2 cooling 1075 1640 2056 3700 Power input heating 1065 1670 2126 3500 3,21 3,26 3,21 3,21 2,81 3,61 3,64 3,41 3,41 3,38...