4-5. Installing Work Clamp

Tools Needed:
3/4 in

4-6. Installing Welding Gun

4-7. Setting Gun Polarity For Wire Type

Shown as shipped − Electrode Positive (DCEP): For solid steel,
stainless steel, aluminum, or flux core with gas wires (GMAW).
Electrode Negative (DCEN): Reverse lead connections at
terminals from that shown above for gasless flux core wires
(FCAW). Drive assembly becomes negative.
OM-1330 Page 12
Changing Polarity
Wire Drive
Assembly Lead
D
+
-
Positive Terminal
1
2
3
1
3
4
2
Work Clamp Lead
D
Negative Terminal
1
Work Cable
2
Boot
Route cable through front panel
opening. Slide boot onto work
cable.
3
Negative (−) Output Terminal
Connect cable to terminal and
cover connection with boot.
Close door.
1
Drive Assembly
2
Gun Securing Knob
3
Gun End
Loosen securing knob. Insert gun
end through opening until it bottoms
against drive assembly (make sure
gun end does not touch drive rolls).
Tighten knob.
4
Gun Trigger Plug
Insert plug into receptacle, and
tighten threaded collar.
Close door.