Download Print this page
Mitsubishi Electric PLFY-P VBM-E Installation Manual
Mitsubishi Electric PLFY-P VBM-E Installation Manual

Mitsubishi Electric PLFY-P VBM-E Installation Manual

Air-conditioners for building application, indoor unit
Hide thumbs Also See for PLFY-P VBM-E:

Advertisement

Quick Links

Air-Conditioners For Building Application
INDOOR UNIT
PLFY-P·VBM-E
INSTALLATION MANUAL
For safe and correct use, read this manual and the outdoor unit installation manual thoroughly before installing
the air-conditioner unit.
INSTALLATIONSHANDBUCH
Aus Sicherheitsgründen und zur richtigen Anwendung vor Installation der Klimaanlage die vorliegende Bedie-
nungsanleitung und das Installationshandbuch gründlich durchlesen.
MANUEL D'INSTALLATION
Avant d'installer le climatiseur, lire attentivement ce manuel, ainsi que le manuel d'installation de l'appareil exté-
rieur pour une utilisation sûre et correct.
INSTALLATIEHANDLEIDING
Lees deze handleiding en de installatiehandleiding van het buitenapparaat zorgvuldig door voordat u met het
installeren van de airconditioner begint.
MANUAL DE INSTALACIÓN
Para un uso seguro y correcto, lea detalladamente este manual de instalación antes de montar la unidad de
aire acondicionado.
MANUALE DI INSTALLAZIONE
Per un uso sicuro e corretto, prima di installare il condizionatore d'aria leggere attentamente il presente manuale
ed il manuale d'installazione dell'unità esterna.
MANUAL DE INSTALAÇÃO
Para uma utilização segura e correcta, leia atentamente este manual e o manual de instalação da unidade exte-
rior antes de instalar o aparelho de ar condicionado.
INSTALLATIONSMANUAL
Læs af sikkerhedshensyn denne manual samt manualen til installation af udendørsenheden grundigt, før du
installerer klimaanlægget.
INSTALLATIONSMANUAL
Läs bruksanvisningen och utomhusenhetens installationshandbok noga innan luftkonditioneringen installeras så
att den används på ett säkert och korrekt sätt.
INSTALLASJONSHÅNDBOK
installeres.
For use with the R410A
Bei Verwendung von R410A
A utiliser avec le R410A
Bij gebruik van R410A
Para utilizar con el R410A
Uso del refrigerante R410A
FOR INSTALLER
FÜR INSTALLATEURE
POUR L'INSTALLATEUR
VOOR DE INSTALLATEUR
PARA EL INSTALADOR
PER L'INSTALLATORE
PARA O INSTALADOR
TIL INSTALLATØREN
FÖR INSTALLATÖREN
FOR MONTØR
DLA INSTALATORA
Para utilizaçao com o R410A
R410A ile beraber kullanmak için
For bruk med R410A
English (GB)
Deutsch (D)
Français (F)
Nederlands (NL)
Español (E)
Italiano (I)
Português (P)
Dansk (DA)
Svenska (SV)
Türkçe (TR)
Norsk (NO)
Polski (PL)
-

Advertisement

loading
Need help?

Need help?

Do you have a question about the PLFY-P VBM-E and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Mitsubishi Electric PLFY-P VBM-E

  • Page 1 Air-Conditioners For Building Application INDOOR UNIT PLFY-P·VBM-E For use with the R410A Bei Verwendung von R410A Para utilizaçao com o R410A A utiliser avec le R410A R410A ile beraber kullanmak için Bij gebruik van R410A Para utilizar con el R410A For bruk med R410A Uso del refrigerante R410A INSTALLATION MANUAL...
  • Page 2 Contents 1. Safety precautions ..................2 4. Electrical work ...................6 2. Installing the indoor unit ................2 5. Installing the grille ..................10 3. Refrigerant pipe and drain pipe ..............4 6. Test run ....................13 Note: : Indicates an action that must be avoided. : Indicates that important instructions must be followed.
  • Page 3 950 D Caution: 20-45 860-910 C 20-45 810 B accessory with the grille), make an opening in the ceiling so that the main unit can be installed as shown in the diagram. (The method for using the template and the gauge is shown.) * Before using, check the dimensions of template and gauge, because they * The dimensions of ceiling opening can be regulated within the range shown in...
  • Page 4 A Suspension bolt B Ceiling Suspend the main unit as shown in the diagram. C Nut Figures given in parentheses represent the dimensions in case of installing optional D Washer (with insulation) multi function casement. E Mounting plate 1. In advance, set the parts onto the suspension bolts in the order of the washers F Washer (without insulation) (with insulation), washers (without insulation) and nuts (double).
  • Page 5 R410A Flare nut O.D. Liquid pipe Gas pipe Tightening Tightening Pipe size Pipe size Liquid pipe Gas pipe torque torque (mm) (mm) (mm) (mm) (N.m) (N.m) 49 - 61 49 - 61 34 - 42 34 - 42 Refrigerant pipe and * Do not apply refrigerating machine oil to the screw portions.
  • Page 6 1. Remove the electrical wiring service panel. 2. Remove the electrical box cover. 3. Remove the MA Remote controller terminal cover. 4. Wire the power cable and control cable separately through the respective wiring entries given in the diagram. Leave excess cable so that the electrical box cover can be suspended below the unit during servicing.
  • Page 7 Minimum wire thickness (mm²) Local switch (A) Breaker for wiring Total operating current of the indoor unit Ground-fault interrupter *1 (NFB) Main cable Branch Ground Capacity Fuse F0 = 16 A or less *2 20 A current sensitivity *3 F0 = 25 A or less *2 30 A current sensitivity *3 F0 = 32 A or less *2 40 A current sensitivity *3...
  • Page 8 M1 M2 M1 M2 M1 M2 TB15 TB5 TB15 the connecting cables, refer to the outdoor unit installation manual. core cable. If the distance is more than 10 m, use a 1.25 mm 1 MA Remote controller 2-wire) M1 M2 M1 M2 M1 M2 2 M-NET Remote controller...
  • Page 9 Symbols: MCA: Max. Circuit Amps (= 1.25×FLA) FLA: Full Load Amps IFM: Indoor Fan Motor Output: Fan motor rated output Power supply Model MCA (A) Output (kW) FLA (A) 0.05 0.22 0.05 0.22 0.05 0.22 0.36 0.05 0.29 0.36 0.05 0.29 0.45 0.05...
  • Page 10 Manual vane angle Manual vane angle the next number. M-NET address There is no response from button. the target device. Confirm the state of the air conditioner. Identify unit Check button unit. Input display: Input display: Cur. Address Check Manual vane angle M-NET address approximately 15 seconds, and then check the current state of the...
  • Page 11 1 to open the intake grille. * Do not unlatch the hook for the intake grille. from the grille as indicated by the arrow 2. indicated by the arrow 1 to remove the corner panel. A Intake grille B Grille C Intake grille levers D Grille hook F Corner panel...
  • Page 12 open the cover. A Clamp of the main unit B Electrical box C Indoor controler board The lead wire of grille is passed through the catch for bell mouth of the unit D Catch for bell mouth perfectly. The remaining lead wire is tied with clamp of the unit and put the cover of E Lead wire of grille the unit again with 2 screws.
  • Page 13: Controller Interface

    Warning: Controller interface The following 3 methods are available. Press to save the setting. Press to return to the previous screen. Press to bring up the Main menu. 5 Backlit LCD Operation settings will appear. When the backlight is off, pressing any button turns the backlight on and it will stay lit for a certain period of time depending on the screen.
  • Page 14 Step 2 1 Press the button to go through the operation modes in the order of “Cool” Test run Remain Remain Cool mode: Check the cold air blow off. Pipe Cool Auto * Check the operation of the outdoor unit’s fan. Switch disp.
  • Page 16 950 D 20-45 20-45 860-910 C 810 B 187,5 840 A Min. 1500 Fig. 2-2 120° Fig. 2-3 Fig. 2-4...
  • Page 17 Min. 30 45° ± 2°...
  • Page 18 Refrigerant pipe and insulating material Pipe cover (large) Pipe cover (small) Refrigerant pipe (gas) Refrigerant pipe (liquid) Band Cross-sectional view of connection Pipe Insulating material Squeeze Max. 20m 1.5–2m Max. 15cm...
  • Page 19 M1 M2 S TB15...
  • Page 20 6000 0.01 8 10...
  • Page 21 M1 M2 M1 M2 M1 M2 TB15 TB5 TB15 M1 M2 M1 M2 M1 M2 CN90 CN90 M1 M2 Pair No. M1 M2 Pair No. M1 M2 TB15 TB15 Pair No. CN43 1 2 3 4 5 6 7 8 9 10 SW12 SW11 CN82...
  • Page 22 Horizontal airflow Downward Fixed setting Remote controller setting The airflow direction of The airflow direction of this outlet is fixed this outlet is controlled by in particular direction. the airflow direction setting of remote controller. * When it is cold because of direct airflow, the airflow direction can be fixed horizontally to avoid direct airflow.
  • Page 23 Manual vane angle Manual vane angle M-NET address There is no response from the target device. Confirm the state of the air Identify unit Check button conditioner. Input display: Input display: Cur. Address Check Manual vane angle M-NET address The air conditioner with the vane pointing downward is the target air conditioner.
  • Page 26 Service menu Test run menu Test run Test run Enter maintenance password Input maintenance info. Drain pump test run Function setting Check Self check Service menu: Select: Cursor Cursor...
  • Page 27 Test run Remain Remain Pipe Cool Auto Switch disp. Mode Vane F1 F2...
  • Page 28 This product is designed and intended for use in the residential, commercial and light-industrial environment. this manual before handing it to the customer. RG79F109K01 Printed in UNITED KINGDOM...