DC Voltage (V
Range
200mV
2V
20V
200V
600V
Input Impedance: 10MΩ for all ranges
AC Voltage (V
Range
20V
200V
600V
Input Impedance: 10MΩ for all ranges
Frequency Range: 40 to 400Hz
DC Current (A
Range
20mA
200mA
10A
Overload Protection: 0.2A/250V resettable fuse, 10A/250V fuse for 10A range
Max. Input Current: 10A (max.10 seconds every 15 minutes)
AC Current (A
Range
20mA
200mA
10A
Overload Protection: 0.2A/250V resettable fuse, 10A/250V fuse for 10A range
Frequency Range: 40 to 400Hz
Max. Input Current: 10A (max.10 seconds every 15 minutes)
Frequency Range: 40 to 400Hz
Resistance
Range
200Ω
2kΩ
20kΩ
200kΩ
2MΩ
20MΩ
Capacitance
Range
200nF
2µF
20µF
29.04.2010
)
Resolution
100µV
1mV
10mV
100mV
1V
)
Resolution
10mV
100mV
1V
)
Resolution
10µA
100µA
10mA
)
Resolution
10µA
100µA
10mA
Resolution
0.1Ω
1Ω
10Ω
100Ω
1kΩ
10kΩ
Resolution
100pF
10nF
EVM892
1nF
13
Accuracy
± 0.8% of rdg ± 2 digits
± 1.0% of rdg ± 2 digits
Accuracy
± 0.8% of rdg ± 3 digits
± 1.2% of rdg ± 3 digits
Accuracy
± 1.2% of rdg ± 2 digits
± 1.5% of rdg ± 1 digit
± 2.0% of rdg ± 5 digits
Accuracy
± 1.2% of rdg ± 2 digits
± 1.8% of rdg ± 2 digits
± 3.0% of rdg ± 7 digits
Accuracy
± 0.8% of rdg ± 3 digits
± 0.8% of rdg ± 2 digits
± 1.8% of rdg ± 2 digits
Accuracy
± 4% of rdg ± 5 digits
©Velleman nv