OPERATING INSTRUCTIONS & INSTALLATION
Assumption of the ambient temp of higher than 64.4 °F/ 18 °C
Low water pressure
Initial 2hr standby
Power On
High water pressure
High water pressure → Low water pressure
High water pressure
Low water pressure → High water pressure
3) Ice Making
It is until the water in the ICE-TRAY after the completion of Water Supply gets frozen completely and the ice
making movement is completed by the temp of the ice making temp pickup part using the ice maker sensor
(THERMISTOR).
3-1) After water is supplied to the ICE-TRAY, check the temp pickup part of the ice maker sensor after the
Ejection Stand-By Time for 58(58~110) min. (For the No Water Supply, 90 min) and judge whether the temp
of the ice maker sensor is below (1.4°F/-17°C).
3-2) If the ice maker sensor maintains the temp below (1.4°F/-17°C) for 5 min. It is judged that ice making is
completed. However, do not check the ice maker sensor within the Ejection Stand-By Time from the point of
Water Supply. (Protection function when the sensor is faulty or the cold air leaks.)
3-3) Stand-by for 1 CYCLE: After the completion of the initialization by POWER ON, it stands by for 1 CYCLE
(2hr.) and operates the Ejection although the temp condition of the ice maker sensor is satisfied.
3-4) As long as the temp of the temp sensing part maintains below (1.4°F/-17°C) for more than 5 min, the
Ejection will be carried out. If the temp fluctuates below (1.4°F/-17°C) above (1.4°F/-17°C), the Ejection will
be carried out after 5 min. at the temp below (1.4°F/-17°C) while counting the Stand-by Time entering the
temp below (1.4°F/-17°C).
5s
95+(5)min
No Water Supply
5s
58+(5)min
Water Supply
5s
5s
58+(5)min
95+(5)min
Water Supply
No Water Supply
Low water pressure
5s 1.5s 1s
2s
Water Supply
Low water pressure
5s 1.5s
70+(5)min
No Water Supply
5s
5s
95+(5)min
No Water Supply
Water Supply
when the Ice cube on
the tray cube which the
sensor is attached is
not removed.
5s 1.5s
70+(5)min
No Water Supply
5s
58+(5)min
58+(5)min
Water Supply
High water pressure
22
5s
1.5s 1s
70+(5)min
No Water Supply
58+(5)min
When the ice cube on
the tray cube which the
sensor is attached is
removed.
5s 1.5s 1s
58+(5)min
Water Supply
5s
58+(5)min
Water Supply